Catalog item
Request a quoteTRANSFORMER,POWER
5950FSC
01NCB code
055-3984Item number
NIIN 01-055-3984
- Unit price
- $2,745.72
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 32496
- PINC
- 0032496
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 04-FEB-78
- Precious metals indicator
- U
- Hazardous material indicator
- P
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $2,745.72 | 1 | U | 0 | 9B----- | $0.00 | N |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $2,745.72 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| C15899 | 72149 ELECTRONIC TRANSFORMER CORP DIV ELECTRONIC TRANSFORMER CORPORATION | A | 5 | 2 | 5 | ZZ | ||
| TTI-11563 | 96253 TRANSFORMER TECHNICIANS INC | H | 5 | 9 | A | TX | 4 | B |
| 25P223188-01 | 98738 HERLEY CHICAGO DBA STEWART WARNER ELECTRONICS | A | 3 | 2 | A | TX | ||
| 10132732 | A486G NIMIKKEISTOKESKUS NCB FINLAND | A | 6 | 9 | 9 | WF | 4 | B |
| PEI 8157 | 13483 PRECISION ELECTRONICS, INC | A | 5 | 2 | 5 | ZZ |
Characteristics
| RELIABILITY INDICATOR | NOT ESTABLISHED |
|---|---|
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
| OVERALL LENGTH | INCHES MINIMUM 1.234 AND INCHES MAXIMUM 1.266 |
| MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES MINIMUM 0.177 AND INCHES MAXIMUM 0.197 |
| FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE |
| TRANSFORMER WINDING CONNECTION TYPE | WYE-WYE |
| WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE |
| BODY WIDTH | INCHES MINIMUM 1.615 AND INCHES MAXIMUM 1.635 |
| BODY HEIGHT | INCHES MINIMUM 1.365 AND INCHES MAXIMUM 1.385 |
| MAXIMUM OPERATING TEMP | CELSIUS 170.0 |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.215 AND INCHES MAXIMUM 1.235 |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| MOUNTING FACILITY QUANTITY | 2 |
| MOUNTING METHOD | SINGLE GROUP BRACKET(S) AND UNTHREADED HOLE(S) |
| WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 3 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC NOMINAL 541.9 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC NOMINAL 689.6 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY AMPERES AC NOMINAL 4.03 |
| WINDING POWER RATING | SINGLE COMPONENT THIRD SECONDARY WATTS 25.0 |
| WINDING POWER RATING | SINGLE COMPONENT SECOND SECONDARY WATTS 11.0 |
| WINDING POWER RATING | SINGLE COMPONENT FIRST SECONDARY WATTS 14.0 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 20.30 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 200.00 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 20.30 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 6.20 |
| TERMINAL TYPE AND QUANTITY | EYELET 13 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WF01 | WF | 01-APR-11 | WF | 81 | WF | ||||||||
| N9BN | DN | 3 | C | 01-JUN-06 | Z | KE | GX | 01 | GH | 5D | GX | KE | N9ND |
Service data
Navy
- COG
- 9B
Freight
- ACTY CD
- TX
- NMFC
- 063420
- NMFC sub
- Z
- Uniform freight class
- 35355
- Less than truckload
- W
- Water commodity code
- 595
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- TRANSFORMERS,NOI,OR TRANSFORMER PAR
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 60Z0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 10Physical protection
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- GBMIL-PRF-121, greaseproof, waterproof barrier
- Cush dun
- 00No requirement
- THK
- 0Not applicable
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- ECASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- UItems or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
- Unit pack weight
- 1.0000
- UP SZ MAXB
- 1.40000
- UP SZ MAXL
- 1.60000
- UP SZ MAXH
- 1.30000
- Unit pack cube
- 0.0010
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 10-FEB-1978
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.