Catalog item

TRANSFORMER,POWER

5950FSC
01NCB code
071-5247Item number
NIIN 01-071-5247
Request a quote
Unit price
$2,870.82
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
09-FEB-79
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8504314035

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$2,870.821U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$2,870.821U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
1882972964
ROBERT M. HADLEY COMPANY, INC.
A325TX4D
984916-1B82577
RAYTHEON COMPANY DBA RAYTHEON
A72ATX4D
86199282577
RAYTHEON COMPANY DBA RAYTHEON
A595TX4B
310-13992-0195266
OECO, LLC DBA PACIFIC SCIENTIFIC OECO DIV FIRE SAFETY AND POWER SYSTEMS
A525TX4D

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.600
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.600
MOUNTING HOLE DIAMETERSINGLE GROUP INCHES NOMINAL 0.156
FREQUENCY RATINGSINGLE COMPONENT KILOHERTZ NOMINAL 15.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
MAXIMUM TRANSFORMER POWER RATINGSINGLE COMPONENT WATTS 28.0
BODY LENGTHINCHES MAXIMUM 3.290
BODY WIDTHINCHES MAXIMUM 3.000
BODY HEIGHTINCHES MAXIMUM 3.000
MAXIMUM OPERATING TEMPCELSIUS 130.0
INCLOSURE TYPEFULLY INCLOSED
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP UNTHREADED HOLE(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 5
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY AMPERES AC MAXIMUM 120.0
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 1.5
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 1.5
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 120.0
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 4.90
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 131.50
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 4.90
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 4.90
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 4.90
SPECIAL FEATURES1 PRIMARY WINDING; 5 SECONDARY WINDINGS
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 12

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
YD01YD01-AUG-17YD81YD
ZJ01ZJ01-APR-25ZJ81ZJ
FXGXDF2G01-JUN-06ZSXGX01SX5DGX TUFXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
60Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
A
1/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
2.5000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0350
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
09-FEB-1979
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.