Catalog item

TRANSFORMER,POWER

5950FSC
01NCB code
080-4817Item number
NIIN 01-080-4817
Request a quote
Unit price
$84,450.29
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
27-JUL-79
Precious metals indicator
A
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$84,450.291U0NSF9WF-V$0.00F
01-OCT-2026DSJSMSEA0.0000$84,450.291U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
695R298G0197942
NORTHROP GRUMMAN SYSTEMS CORPORATION DBA NORTHROP GRUMMAN SYSTEMS CORP
A32EZZ
593R373A0197942
NORTHROP GRUMMAN SYSTEMS CORPORATION DBA NORTHROP GRUMMAN SYSTEMS CORP
A59ASB4B
593R373A0297942
NORTHROP GRUMMAN SYSTEMS CORPORATION DBA NORTHROP GRUMMAN SYSTEMS CORP
A12AZZ

Characteristics

OVERALL LENGTHINCHES NOMINAL 4.070
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.530
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.730
OVERALL HEIGHTINCHES NOMINAL 3.350
OVERALL WIDTHINCHES NOMINAL 2.270
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT THREE PHASE TO THREE PHASE
TRANSFORMER WINDING CONNECTION TYPEWYE-DELTA-WYE
INCLOSURE TYPEFULLY INCLOSED
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED HOLE(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 6
THREAD QUANTITY PER INCH32
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.138
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY AMPERES AC MAXIMUM 2.2
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 3.3
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 4.2
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 2.3
WINDING POWER RATINGSINGLE COMPONENT SINGLE PRIMARY VOLTS-AMPERES 585.0
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 22.60
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 10.40
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 200.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 34.70
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 16.60
SPECIAL FEATURESCURRENT RATING FOR 5TH SEC 2.3 AAC,FOR 6TH SEC 0.163 AAC
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTURRET 21

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
WP01WP01-FEB-07WP81WP
YD01YD01-AUG-17YD81YD
ZB01ZB01-APR-91ZB81ZB
ZJ01ZJ01-APR-25ZJ81ZJ
FUGXDF3B01-JUL-05ZSUGX01SU5DGX TUFUTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
WF
PVC
V
ERRC
N

Freight

ACTY CD
SU
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
3.7000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0430
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
27-JUL-1979
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.