Catalog item

TRANSFORMER,POWER

5950FSC
01NCB code
096-1538Item number
NIIN 01-096-1538
Request a quote
Unit price
$202.12
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
14-JUN-80
Precious metals indicator
A
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$202.121U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$202.121U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
TP-210729525
HYTRONICS CORP.
A525TX
A1-1460853854
MAGNESPEC INC
A525ZZ
A1-14600-A95970
MTE CORP MILWAUKEE TRANSFORMER CO
A595TXB
A1-1460895970
MTE CORP MILWAUKEE TRANSFORMER CO
A595TX
1655910138
ASTRONAUTICS CORPORATION OF AMERICA
A321TX4D
122084-510138
ASTRONAUTICS CORPORATION OF AMERICA
A595TXB

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
OVERALL LENGTHINCHES MAXIMUM 1.950
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.325
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 0.950
OVERALL HEIGHTINCHES MAXIMUM 1.700
OVERALL WIDTHINCHES MAXIMUM 1.600
FREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 380.0 AND HERTZ MAXIMUM 420.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL
MAXIMUM OPERATING TEMPCELSIUS 130.0
INCLOSURE TYPEFULLY INCLOSED
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED HOLE(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 3
THREAD QUANTITY PER INCH40
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.112
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES DC MAXIMUM 150.0
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES DC MAXIMUM 250.0
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES DC MAXIMUM 200.0
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 72.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 50.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 23.00
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 12

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
ZK01ZK01-JUL-00ZK81ZK
FXGXDF3D01-JUN-06ZSXGX01SX5DGX TUFXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.4000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0210
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
14-JUN-1980
NIIN status code
0

Cancelled and replaced NIINs

FSC
5950
Cancelled NIIN
5950-01-107-5056
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.