Catalog item

TRANSFORMER,POWER

5950FSC
01NCB code
100-8559Item number
NIIN 01-100-8559
Request a quote
Unit price
$697.19
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
14-SEP-80
Precious metals indicator
U
Hazardous material indicator
P
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DMJSMSEA0.0000$697.191U0Z15B2---$0.00M
01-OCT-2026DNJSMSEA0.0000$697.191U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$697.191U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
WE165626543
WEMS ELECTRONICS TRANSFORMER GROUP
A595TX4B
1203053854
MAGNESPEC INC
A525TX4D
1203076493
BELL INDUSTRIES INC J W MILLER MAGNETICS DIV
A595TXB
1414897214
OWENS-CORNING FIBERGLAS CORP SUPPLY DIV
H595TX4B
88825204971
RANTEC MICROWAVE SYSTEMS, INC. DBA RANTEC MICROWAVE SYSTEMS INC
AC11ZZAC
88825213973
LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISION
R391TX4D
WE165615634
MAGNETIKA INC
A525TX

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.625
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.750
MOUNTING HOLE DIAMETERSINGLE GROUP INCHES NOMINAL 0.161
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT THREE PHASE TO THREE PHASE
TRANSFORMER WINDING CONNECTION TYPEDELTA-DELTA
WINDING SHIELDING METHODSINGLE COMPONENT INTERNALLY SHIELDED
BODY LENGTHINCHES MAXIMUM 3.810
BODY WIDTHINCHES MAXIMUM 3.500
BODY HEIGHTINCHES MAXIMUM 1.800
MAXIMUM OPERATING TEMPCELSIUS 125.0
INCLOSURE TYPEFULLY INCLOSED
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP UNTHREADED HOLE(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 3
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES DC MAXIMUM 1.0
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES DC MAXIMUM 9.0
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES DC MAXIMUM 0.05
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 10.00
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 3.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 200.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 37.00
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 12

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
MC49DM1L01-JUN-06ZPAGX01PA5DGX PAMC13
N9BNDN1L01-JUN-06ZKEGX01GH5DGXKEN9ND

Service data

Navy

COG
9B

Marine Corps

SAC
1
CEC
5
MEC
B2

Freight

ACTY CD
TX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
3.2000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0430
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
14-SEP-1980
NIIN status code
0

Request a quote