Catalog item
Request a quoteTRANSFORMER,POWER
5950FSC
01NCB code
110-4084Item number
NIIN 01-110-4084
- Unit price
- $2,477.73
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 32496
- PINC
- 0032496
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 31-MAR-81
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- P
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $2,477.73 | 1 | U | 0 | 9BT1--9 | $0.00 | N |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $2,477.73 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
- Part number
- 120-0908-00
- CAGE
- 80009TEKTRONIX, INC.
- CAGE status
- A
- RNCC
- 3
- RNVC
- 2
- Document availability code
- 5
- RNAAC
- HD
- RNFC
- 4
- RNSC
- A
Characteristics
| RELIABILITY INDICATOR | NOT ESTABLISHED |
|---|---|
| FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 30.0 AND HERTZ MAXIMUM 400.0 |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL |
| BODY LENGTH | INCHES MAXIMUM 3.250 |
| BODY WIDTH | INCHES MAXIMUM 2.875 |
| BODY HEIGHT | INCHES NOMINAL 3.750 |
| INCLOSURE TYPE | FULLY INCLOSED |
| MOUNTING METHOD | SINGLE GROUP TERMINAL |
| WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 6 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 4.0 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT FOURTH SECONDARY AMPERES AC MAXIMUM 0.8 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 230.0 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 1.42 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT ALL PRIMARY AC VOLTS NOMINAL 110.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 120.00 AND AC VOLTS NOMINAL 220.00 AND AC VOLTS NOMINAL 230.00 AND AC VOLTS NOMINAL 240.00 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 10.50 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 20.90 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 151.00 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 14.50 |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 27 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WP01 | WP | 01-JAN-04 | WP | 81 | WP | ||||||||
| YD01 | YD | 01-AUG-17 | YD | 81 | YD | ||||||||
| YW01 | YW | 01-AUG-00 | YW | 81 | YW | ||||||||
| ZW01 | ZW | 01-NOV-98 | ZW | 81 | ZW | ||||||||
| N9BN | DN | 5 | H | 01-JUN-06 | Z | HD | GX | 01 | GH | 5D | GX | HD GT | N9ND |
Service data
Navy
- COG
- 9B
- SMIC
- T1
- SMCC
- 9
Freight
- ACTY CD
- HD
- NMFC
- 063420
- NMFC sub
- Z
- Uniform freight class
- 35355
- Less than truckload
- W
- Water commodity code
- 595
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- TRANSFORMERS,NOI,OR TRANSFORMER PAR
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 4.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0280
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
- Supplemental instructions
- IP025: PACKAGING, MARKING,
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 31-MAR-1981
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.