Catalog item

TRANSFORMER,POWER

5950FSC
01NCB code
159-6169Item number
NIIN 01-159-6169
Request a quote
Unit price
$1,822.28
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
11-AUG-83
Precious metals indicator
A
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$1,822.281U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,822.281U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
5950PL08205889009H
JEDNOLITY INDEKS MATERIALOWY - UNIFORM MATERIAL INDEX
A699WP4B
1C734497953
GE AVIATION SYSTEMS LLC DBA GE AVIATION SYSTEMS LLC
A32ATX
1C7344-197953
GE AVIATION SYSTEMS LLC DBA GE AVIATION SYSTEMS LLC
AC16ZZAC
5254-40505869
RAYTHEON COMPANY DIV RMD STRATEGIC
A525TX

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 4.468
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.500
MOUNTING HOLE DIAMETERSINGLE GROUP INCHES NOMINAL 0.203
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 60.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT THREE PHASE TO THREE PHASE
TRANSFORMER WINDING CONNECTION TYPEWYE-WYE
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL
BODY LENGTHINCHES NOMINAL 6.000
BODY WIDTHINCHES MAXIMUM 4.700
BODY HEIGHTINCHES MAXIMUM 3.500
MAXIMUM OPERATING TEMPCELSIUS 115.0
INCLOSURE TYPEFULLY INCLOSED
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP UNTHREADED HOLE(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 6
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 6.9
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 6.9
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC MAXIMUM 580.0
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 1.7
WINDING OPERATING VOLTAGESINGLE COMPONENT ALL PRIMARY AC VOLTS MINIMUM 103.50 AND AC VOLTS MAXIMUM 126.50
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 7.90
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 15.50
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 10.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 15.70
SPECIAL FEATURES1 PRIMARY; 6 SECONDARYS
TERMINAL TYPE AND QUANTITYPIN 30

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-APR-04WP81WP
YB01YB01-APR-91YB81YB
ZW01ZW01-DEC-05ZW81ZW
N9BNDN1R01-NOV-05ZHDGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
14.7000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.6660
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
11-AUG-1983
NIIN status code
0

Request a quote