Catalog item

TRANSFORMER,POWER

5950FSC
01NCB code
193-5089Item number
NIIN 01-193-5089
Request a quote
Unit price
$609.43
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
05-NOV-84
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8504314035

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$609.431U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$609.431U0NSF9EH-V$0.00F
01-OCT-2026DMJSMSEA0.0000$609.431U0Z15B2---$0.00M
01-OCT-2026DNJSMSEA0.0000$609.431U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$609.431U0N-------$0.00I
01-OCT-2026GPJSMSEA0.0000$609.431U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
M27/300-0381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22ETX
MIL-T-27/30081349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETXB
MIL-PRF-27/30081349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
OVERALL LENGTHINCHES NOMINAL 3.562
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.625
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.125
OVERALL WIDTHINCHES NOMINAL 3.062
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 60.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
MAXIMUM TRANSFORMER POWER RATINGSINGLE COMPONENT WATTS 3.6
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE
BODY HEIGHTINCHES NOMINAL 3.875
MAXIMUM OPERATING TEMPCELSIUS 105.0
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED STUD(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 1
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.164
WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE SECONDARY AMPERES AC NOMINAL 10.0
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 105.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 125.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 2.50
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-T-27
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTURRET 6
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-T-27 TO 300

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YB01YB01-SEP-09YB81YB
ZH01ZH01-APR-91ZH81ZH
A918DA1T01-JUN-06ZCDGX01CD5DCD GXCLA196
C911GP1T01-JUN-06GX01XG5DXG GXC007
BGX1GE1T01-JUN-06GX01485DGX 48BTX1
FXGXDF1T01-JUN-06ZSXGX01SX5DGX TUFXTX
MC49DM1T01-JUN-06ZPAGX01PA5DGX PAMC13
N9BNDN1T01-JUN-06ZGHGX01GH5DGXHDNIND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2

Freight

ACTY CD
TX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
5.3000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.1250
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
85114

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
5950-00-770-5868ETX12-JAN-19790
5950-01-065-4287ETX04-JAN-19830
BTX20-JAN-19830
ETX04-JAN-19830
ETX12-JAN-19790

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.