Catalog item

TRANSFORMER,POWER

5950FSC
01NCB code
199-9077Item number
NIIN 01-199-9077
Request a quote
Unit price
$1,385.10
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
28-JAN-85
Precious metals indicator
A
Hazardous material indicator
P
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$1,385.101U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,385.101U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
170180-192755
NORTHROP GRUMMAN SYSTEMS CORP DBA NORTHROP GRUMMAN SYSTEMS CORP
A32ATX
TD216504799
M T E CORPORATION
A595TX

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 3.720 AND INCHES MAXIMUM 3.780
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 3.160 AND INCHES MAXIMUM 3.340
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 60.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE
BODY LENGTHINCHES MAXIMUM 4.690
BODY WIDTHINCHES MAXIMUM 4.000
BODY HEIGHTINCHES MAXIMUM 4.000
MAXIMUM OPERATING TEMPCELSIUS 130.0
INCLOSURE TYPEFULLY INCLOSED
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED HOLE(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 7
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.190
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES AC NOMINAL 1.8
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC NOMINAL 360.0
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC NOMINAL 9.0
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC NOMINAL 800.0
WINDING POWER RATINGSINGLE COMPONENT THIRD SECONDARY VOLTS-AMPERES 27.0
WINDING POWER RATINGSINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 171.0
WINDING POWER RATINGSINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 17.4
WINDING POWER RATINGSINGLE COMPONENT FOURTH SECONDARY VOLTS-AMPERES 4.9
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 15.00
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 19.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 21.80
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 13.70
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 109.25 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 120.75
SPECIAL FEATURESONE PRIMARY WINDING AND SEVEN SECONDARY WINDINGS
THREAD SERIES DESIGNATORSINGLE GROUP UNF
TERMINAL TYPE AND QUANTITYEYELET 17 AND WIRE HOOK 3

MOE rules

MOE rule
N9BN
MOE CD
DN
AMC
3
AMSC
C
Date assigned
01-JUL-05
IMC
Z
IMCA
HD
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX
Supp collab
HD
Fmr MOE rl
N9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
E5
ASTM D5118/D5118M, fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
20.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.5000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI rev
Y
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
28-JAN-1985
NIIN status code
0

Request a quote