Catalog item

TRANSFORMER,POWER

5950FSC
01NCB code
214-4200Item number
NIIN 01-214-4200
Request a quote
Unit price
$868.67
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
10-AUG-85
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$868.671U0NSF9AI-E$0.00F
01-OCT-2026DSJSMSEA0.0000$868.671U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
3L0146E00122915
NORTHROP GRUMMAN CORP ELECTRONIC SYSTEMS DEFENSIVE SYSTEM DIV
A122SB
189823591
FRICK-GALLAGHER MFG. CO.
H595SBB
1406753854
MAGNESPEC INC
A325SB

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
OVERALL LENGTHINCHES NOMINAL 1.800
OVERALL HEIGHTINCHES NOMINAL 0.900
OVERALL WIDTHINCHES NOMINAL 1.800
FREQUENCY RATINGSINGLE COMPONENT KILOHERTZ MINIMUM 18.5 AND KILOHERTZ MAXIMUM 25.6
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
INCLOSURE TYPEFULLY INCLOSED
MOUNTING METHODSINGLE GROUP TERMINAL
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 4 AND SECONDARY 3
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD PRIMARY AMPERES AC MINIMUM 0.196 AND AMPERES AC MAXIMUM 0.204
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES DC MINIMUM 0.54 AND AMPERES DC MAXIMUM 0.56
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES DC MINIMUM 0.098 AND AMPERES DC MAXIMUM 0.102
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND PRIMARY AMPERES DC MINIMUM 0.137 AND AMPERES DC MAXIMUM 0.143
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES DC MINIMUM 0.147 AND AMPERES DC MAXIMUM 0.153
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH PRIMARY AMPERES DC MINIMUM 10.78 AND AMPERES DC MAXIMUM 11.22
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS MINIMUM 35.47 AND AC VOLTS MAXIMUM 36.91
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND PRIMARY AC VOLTS MINIMUM 10.44 AND AC VOLTS MAXIMUM 10.86
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD PRIMARY AC VOLTS MINIMUM 6.26 AND AC VOLTS MAXIMUM 6.52
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST PRIMARY AC VOLTS MINIMUM 64.70 AND AC VOLTS MAXIMUM 67.60
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS MINIMUM 20.87 AND AC VOLTS MAXIMUM 21.73
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS MINIMUM 28.17 AND AC VOLTS MAXIMUM 29.31
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH PRIMARY AC VOLTS MINIMUM 6.02 AND AC VOLTS MAXIMUM 6.26
TERMINAL TYPE AND QUANTITYPIN 26

MOE rules

MOE rule
FUGX
MOE CD
DF
AMC
2
AMSC
R
Date assigned
01-JUN-06
IMC
Z
IMCA
SU
PICA
GX
PICA LOA
01
SICA
SU
SICA LOA
5D
Auth collab
GX TU
Fmr MOE rl
FUTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
AI
PVC
E
ERRC
N

Freight

ACTY CD
SU
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
6
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Unit pack weight
0.3000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0170
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
85357

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
10-AUG-1985
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.