Catalog item
Request a quoteTRANSFORMER,POWER
5950FSC
01NCB code
293-2233Item number
NIIN 01-293-2233
- Unit price
- $8,566.66
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 32496
- PINC
- 0032496
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 29-JAN-89
- Precious metals indicator
- A
- Hazardous material indicator
- P
Management
- Effective date
- 01-OCT-2026
- Major organizational entity
- DS
- Acquisition advice code
- Y
- Source of supply
- SMS
- Unit of issue
- EA
- Unit of measure quantity
- 0.0000
- Unit price
- $8,566.66
- Quantity per unit pack
- 1
- Controlled inventory item code
- U
- Shelf-life code
- 0
- Management control
- -------
- Net price
- $0.00
- USC
- I
Part numbers
- Part number
- 064-23006-09
- CAGE
- 95266OECO, LLC DBA PACIFIC SCIENTIFIC OECO DIV FIRE SAFETY AND POWER SYSTEMS
- CAGE status
- A
- RNCC
- 3
- RNVC
- 2
- Document availability code
- B
- RNAAC
- TX
Characteristics
| RELIABILITY INDICATOR | NOT ESTABLISHED |
|---|---|
| OVERALL LENGTH | INCHES MAXIMUM 2.525 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | FIRST MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.225 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SECOND MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.054 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SECOND MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.020 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | FIRST MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.150 |
| OVERALL WIDTH | INCHES MAXIMUM 1.550 |
| FREQUENCY RATING | SINGLE COMPONENT KILOHERTZ NOMINAL 25.0 |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| BODY HEIGHT | INCHES MINIMUM 1.118 AND INCHES MAXIMUM 1.128 |
| MAXIMUM OPERATING TEMP | CELSIUS 155.0 |
| INCLOSURE TYPE | FULLY INCLOSED |
| MOUNTING FACILITY QUANTITY | 2 |
| MOUNTING METHOD | ALL GROUPINGS THREADED BUSHING |
| WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| NOMINAL THREAD SIZE | ALL GROUPINGS INCHES 0.138 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE PRIMARY AMPERES AC NOMINAL 8.5 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES AC MINIMUM 720.0 AND AMPERES AC MAXIMUM 6.3 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 39.50 AND AC VOLTS NOMINAL 43.00 AND AC VOLTS NOMINAL 55.10 AND AC VOLTS NOMINAL 68.90 AND AC VOLTS NOMINAL 81.00 AND AC VOLTS NOMINAL 84.50 AND AC VOLTS NOMINAL 124.00 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 17.33 |
| SPECIAL FEATURES | TERMINAL CONNECTIONS 2 AND 8 ARE SPLIT TO PROVIDE MULTIPLE HOOK UP |
| PROPRIETARY CHARACTERISTICS | PACS |
| THREAD SERIES DESIGNATOR | ALL GROUPINGS UNIFIED NATIONAL COARSE (UNC) |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 4 AND PIN 12 |
MOE rules
- MOE rule
- DGX1
- MOE CD
- DS
- AMC
- 5
- AMSC
- H
- Date assigned
- 01-JUN-06
- PICA
- GX
- PICA LOA
- 01
- Auth collab
- GX
- Supp collab
- TX
- Fmr MOE rl
- DTX1
Freight
- ACTY CD
- TH
- NMFC
- 063420
- NMFC sub
- Z
- Uniform freight class
- 35355
- Less than truckload
- W
- Water commodity code
- 595
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- TRANSFORMERS,NOI,OR TRANSFORMER PAR
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69Z0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- IP025: PACKAGING, MARKING,
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 91189
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 29-JAN-1989
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.