Catalog item
Request a quoteTRANSFORMER,POWER
5950FSC
01NCB code
300-4959Item number
NIIN 01-300-4959
- Unit price
- $2,141.67
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 32496
- PINC
- 0032496
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 14-MAY-89
- Precious metals indicator
- A
- Hazardous material indicator
- P
- FedMall
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DA | J | SMS | EA | 0.0000 | $2,141.67 | 1 | U | 0 | Z | Q2200X- | $0.00 | A |
| 01-OCT-2026 | DM | J | SMS | EA | 0.0000 | $2,141.67 | 1 | U | 0 | Z | 15B2--- | $0.00 | M |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $2,141.67 | 1 | U | 0 | N | ------- | $0.00 | I |
Part numbers
Characteristics
| RELIABILITY INDICATOR | NOT ESTABLISHED |
|---|---|
| OVERALL LENGTH | INCHES MAXIMUM 5.120 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 4.668 AND INCHES MAXIMUM 4.708 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.700 AND INCHES MAXIMUM 1.750 |
| MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES MINIMUM 0.208 AND INCHES MAXIMUM 0.228 |
| FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 60.0 AND HERTZ MAXIMUM 400.0 |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| BODY WIDTH | INCHES MAXIMUM 2.250 |
| BODY HEIGHT | INCHES MAXIMUM 2.880 |
| MAXIMUM OPERATING TEMP | CELSIUS 155.0 |
| END ITEM IDENTIFICATION | 5820-01-248-4442 RADIO SET |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| MOUNTING FACILITY QUANTITY | 4 |
| MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY AMPERES AC NOMINAL 3.75 |
| WINDING POWER RATING | SINGLE COMPONENT SINGLE SECONDARY VOLTS-AMPERES 88.9 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 23.70 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 80063-S--A-912788 |
| TERMINAL TYPE AND QUANTITY | TURRET 4 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A918 | DA | 3 | C | 01-JUN-06 | Z | CL | GX | 01 | CD | 5D | CD GX | CL | A196 |
| MC49 | DM | 3 | C | 01-JUN-06 | Z | PA | GX | 01 | PA | 5D | GX PA | MC13 |
Service data
Army
- Matcat 1
- Q
- Matcat 2
- 2
- Matcat 3
- 2
- Matcat 4 5
- 00
- ARC
- X
Marine Corps
- SAC
- 1
- CEC
- 5
- MEC
- B2
Freight
- ACTY CD
- TH
- NMFC
- 063420
- NMFC sub
- Z
- Uniform freight class
- 35355
- Less than truckload
- W
- Water commodity code
- 595
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- TRANSFORMERS,NOI,OR TRANSFORMER PAR
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 60F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 10Physical protection
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- DOAny suitable fiber box included in this table may be used (see J.4.9.1).
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 5.0000
- UP SZ MAXB
- 2.30000
- UP SZ MAXL
- 5.10000
- UP SZ MAXH
- 3.30000
- Unit pack cube
- 0.0220
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
- Supplemental instructions
- IP025: PACKAGING, MARKING,
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 14-MAY-1989
- NIIN status code
- 0
Request a quote