Catalog item

TRANSFORMER ASSEMBLY

5950FSC
01NCB code
339-8204Item number
NIIN 01-339-8204
Request a quote
Unit price
$8,547.40
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00449
PINC
0000449
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
31-MAY-91
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8504900020

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNZSMSEA0.0000$8,547.401U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$8,547.401U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
12020-155196
SORA POWER INC. DBA SIGMA DIVISION
A525TX
984882-5B82577
RAYTHEON COMPANY DBA RAYTHEON
A32ATX
321-18050-0595266
OECO, LLC DBA PACIFIC SCIENTIFIC OECO DIV FIRE SAFETY AND POWER SYSTEMS
A525TX
10132963A486G
NIMIKKEISTOKESKUS NCB FINLAND
A699WF4B

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONVIBRATION RESISTANT
OVERALL LENGTHINCHES MAXIMUM 6.030
OVERALL HEIGHTINCHES MAXIMUM 3.570
MOUNTING HOLE DIAMETERSECOND GROUP INCHES NOMINAL 0.500
MOUNTING SLOT WIDTHFIRST GROUP INCHES NOMINAL 0.187
FREQUENCY RATINGALL COMPONENTS KILOHERTZ NOMINAL 10.0
INPUT-OUTPUT PHASE RELATIONSHIPALL COMPONENTS SINGLE PHASE TO SINGLE PHASE
WINDING SHIELDING METHODSECOND COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL
WINDING SHIELDING METHODTHIRD COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL AND INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL
BODY WIDTHINCHES MAXIMUM 3.440
MAXIMUM OPERATING TEMPCELSIUS 130.0
DISTANCE BETWEEN MOUNTING FACILITY CENTERSSECOND MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.500
DISTANCE BETWEEN MOUNTING FACILITY CENTERSTHIRD MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 5.375
DISTANCE BETWEEN MOUNTING FACILITY CENTERSFIRST MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 4.500
MOUNTING TAB WIDTHINCHES NOMINAL 0.625
INCLOSURE TYPEFULLY INCLOSED
MOUNTING FACILITY QUANTITY2
MOUNTING METHODFIRST GROUP SLOT
MOUNTING METHODTHIRD GROUP TAB
MOUNTING METHODSECOND GROUP UNTHREADED HOLE(S)
RATING METHODSECOND COMPONENT FOURTH SECONDARY ELECTRICAL
RATING METHODALL COMPONENTS SECOND SECONDARY ELECTRICAL
RATING METHODALL COMPONENTS THIRD SECONDARY ELECTRICAL
RATING METHODALL COMPONENTS SINGLE PRIMARY ELECTRICAL
RATING METHODFIRST COMPONENT FOURTH SECONDARY ELECTRICAL
RATING METHODALL COMPONENTS FIRST SECONDARY ELECTRICAL
WINDING FUNCTION AND QUANTITYFIRST COMPONENT PRIMARY 1 AND SECONDARY 4
WINDING FUNCTION AND QUANTITYTHIRD COMPONENT PRIMARY 1 AND SECONDARY 3
WINDING FUNCTION AND QUANTITYSECOND COMPONENT PRIMARY 1 AND SECONDARY 4
FEATURES PROVIDEDW/RECTIFIER
WINDING OPERATING CURRENTSECOND COMPONENT SECOND SECONDARY MILLIAMPERES AC NOMINAL 50.0
WINDING OPERATING CURRENTSECOND COMPONENT THIRD SECONDARY MILLIAMPERES AC NOMINAL 35.0
WINDING OPERATING CURRENTFIRST COMPONENT FOURTH SECONDARY MILLIAMPERES AC NOMINAL 30.0
WINDING OPERATING CURRENTSECOND COMPONENT FOURTH SECONDARY AMPERES AC NOMINAL 3.0
WINDING OPERATING CURRENTTHIRD COMPONENT FIRST SECONDARY AMPERES AC NOMINAL 0.01
WINDING OPERATING CURRENTTHIRD COMPONENT THIRD SECONDARY AMPERES AC NOMINAL 0.035
WINDING OPERATING CURRENTSECOND COMPONENT FIRST SECONDARY MILLIAMPERES AC NOMINAL 50.0
WINDING OPERATING CURRENTTHIRD COMPONENT SECOND SECONDARY AMPERES DC NOMINAL 1.2
DC RESISTANCE RATING IN OHMS0.280
DC RESISTANCE RATING IN OHMS0.060
DC RESISTANCE RATING IN OHMS0.100
DC RESISTANCE RATING IN OHMS1.200
DC RESISTANCE RATING IN OHMS2.750
DC RESISTANCE RATING IN OHMS0.090
DC RESISTANCE RATING IN OHMS12.000
DC RESISTANCE RATING IN OHMS0.200
DC RESISTANCE RATING IN OHMS0.040
WINDING POWER RATINGSECOND COMPONENT THIRD SECONDARY VOLTS-AMPERES 5245.8
WINDING POWER RATINGFIRST COMPONENT FOURTH SECONDARY VOLTS-AMPERES 159.07
WINDING POWER RATINGTHIRD COMPONENT FIRST SECONDARY VOLTS-AMPERES 0.2
WINDING POWER RATINGTHIRD COMPONENT SECOND SECONDARY VOLTS-AMPERES 160.2
WINDING POWER RATINGSECOND COMPONENT SECOND SECONDARY VOLTS-AMPERES 3535.0
WINDING POWER RATINGSECOND COMPONENT FIRST SECONDARY VOLTS-AMPERES 300.5
WINDING POWER RATINGSECOND COMPONENT FOURTH SECONDARY VOLTS-AMPERES 18.03
WINDING POWER RATINGTHIRD COMPONENT THIRD SECONDARY VOLTS-AMPERES 7.47
WINDING OPERATING VOLTAGESECOND COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 6.01
WINDING OPERATING VOLTAGEFIRST COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 106.05
WINDING OPERATING VOLTAGEFIRST COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 15.55
WINDING OPERATING VOLTAGEFIRST COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 106.05
WINDING OPERATING VOLTAGESECOND COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 70.70
WINDING OPERATING VOLTAGESECOND COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 149.88
WINDING OPERATING VOLTAGETHIRD COMPONENT SECOND SECONDARY DC VOLTS MINIMUM 130.00 AND DC VOLTS MAXIMUM 137.00
WINDING OPERATING VOLTAGETHIRD COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 178.16 AND AC VOLTS NOMINAL 195.84 AND AC VOLTS NOMINAL 213.57
WINDING OPERATING VOLTAGEFIRST COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 106.05
WINDING OPERATING VOLTAGESECOND COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 14.14
WINDING OPERATING VOLTAGETHIRD COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 15.55
WINDING OPERATING VOLTAGESECOND COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 6.01
WINDING OPERATING VOLTAGETHIRD COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 16.26
WINDING OPERATING VOLTAGEFIRST COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 530.25
TERMINAL TYPE AND QUANTITYWIRE LEAD 36

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WF01WF01-APR-11WF81WF
YB01YB01-AUG-03YB81YB
YW01YW01-JUL-17YW81YW
ZC01ZC01-JUL-97ZC81ZC
N9BNDN1R01-JUN-06ZKEGX01GH5DGXKE GTN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
ZZZZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
ZZZ
Special requirement: see the specific drawing or instruction provided
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
Z
Special requirements - See specific instructions or drawings provided.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
Z
Special requirements – See specific instructions or drawings provided
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Z
Special requirement.
Lvl b
Z
Special requirement.
Lvl c
Z
Special requirement – see specific instructions or drawings provided.
Unit pack weight
5.0000
UP SZ MAXB
3.60000
UP SZ MAXL
6.00000
UP SZ MAXH
3.40000
Unit pack cube
0.0420
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
SPECIAL PACKAGING INSTRUCT

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
31-MAY-1991
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.