Catalog item

CRYSTAL UNIT,QUARTZ

5955FSC
01NCB code
261-7714Item number
NIIN 01-261-7714
Request a quote
Unit price
$21.17
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00196
PINC
0000196
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
19-AUG-87
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8541900000

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
X
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$21.17
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MIL-PRF-3098/2181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413ZZ
CR42/U120K500081349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223ZZ
CR42AU120-500KHZ81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX1B
MILC309881349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX1B

Characteristics

OVERALL LENGTHINCHES MAXIMUM 1.774
TERMINAL LENGTHINCHES MINIMUM 0.223 AND INCHES MAXIMUM 0.248
OVERALL WIDTHINCHES MAXIMUM 0.757
BODY LENGTHINCHES MAXIMUM 1.526
BODY WIDTHINCHES MAXIMUM 0.725
BODY THICKNESSINCHES MAXIMUM 0.317
OVERALL THICKNESSINCHES MAXIMUM 0.352
TERMINAL DIAMETERINCHES MINIMUM 0.048 AND INCHES MAXIMUM 0.052
MODE OF OSCILLATIONFUNDAMENTAL
CIRCUIT RESONANCEANTIRESONANCE
LOAD CAPACITANCE IN PICOFARADSMINIMUM 31.5 AND MAXIMUM 32.5
SHUNT CAPACITANCE IN PICOFARADSMAXIMUM 4.9
SPECIFIED FREQUENCYKILOHERTZ 120.500
FREQUENCY TOLERANCE AT REFERENCE TEMP IN PERCENT-0.003 TO 0.003
FREQUENCY STABILITY IN PERCENT-0.002 TO 0.002
CONTROLLED REFERENCE TEMPCELSIUS 75.0
OPERABLE TEMP RANGECELSIUS -55.0 TO 70.0
CENTER TO CENTER DISTANCE BETWEEN TERMINALSINCHES MINIMUM 0.478 AND INCHES MAXIMUM 0.494
OPERATING TEMP RANGECELSIUS 70.0 TO 80.0
DRIVE LEVEL RATINGMILLIWATTS MINIMUM 1.6 AND MILLIWATTS MAXIMUM 2.4
FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENT-0.003 TO 0.003
EQUIVALENT RESISTANCE VALUE IN OHMSMAXIMUM 4500.0
STYLE DESIGNATOR
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-3098
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-3098 TO 21

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedPICAPICA LOAAuth collab
YA01YA01-JUL-01YA81YA
DGX1DS1T01-JAN-26GX01GX

Freight

ACTY CD
TX
NMFC
063025
NMFC sub
Z
Uniform freight class
34525
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
SEMICONDUCTORS/DEVICES NOI ETC

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
96
Dt stdzn dec
01-JAN-1996
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.