Catalog item

TRANSISTOR

5961FSC
00NCB code
241-3646Item number
NIIN 00-241-3646
Request a quote
Unit price
$28.46
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
20588
PINC
0020588
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
13-AUG-78
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8541500080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$28.461U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$28.461U0NSF9EH-N$0.00F
01-OCT-2026DMJSMSEA0.0000$28.461U0Z15B2B--$0.00M
01-OCT-2026DNJSMSEA0.0000$28.461U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$28.461U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
F223321845
SOLITRON DEVICES, INC.
A525TX
SF5503727014
NATIONAL SEMICONDUCTOR CORPORATION
A525TX1D
F5503727014
NATIONAL SEMICONDUCTOR CORPORATION
A595TXB
151-1005-0080009
TEKTRONIX, INC.
A321TX4D
SKA547001295
TEXAS INSTRUMENTS INCORPORATED
A595TX1D
SPF68504713
FREESCALE SEMICONDUCTOR, INC.
A595TX1D
U149015818
TELCOM SEMICONDUCTOR INC
H596TX4D
J203317856
SILICONIX INCORPORATED DIV SILICONIX
A595TX1D
J242217856
SILICONIX INCORPORATED DIV SILICONIX
A595TX

Characteristics

OVERALL LENGTHINCHES MINIMUM 0.170 AND INCHES MAXIMUM 0.210
TERMINAL LENGTHINCHES MINIMUM 0.500
OVERALL HEIGHTINCHES MINIMUM 0.125 AND INCHES MAXIMUM 0.165
OVERALL WIDTHINCHES MINIMUM 0.175 AND INCHES MAXIMUM 0.205
INTERNAL CONFIGURATIONFIELD EFFECT
JOINT ELECTRONIC DEVICE ENGINEERING COUNCIL/JEDEC/CASE OUTLINE DESIGNATIONTO-92
MOUNTING METHODTERMINAL
TERMINAL CIRCLE DIAMETERINCHES NOMINAL 0.100
SEMICONDUCTOR MATERIALSILICON
VOLTAGE RATING IN VOLTS PER CHARACTERISTICMAXIMUM DRAIN TO GATE VOLTAGE 50.0 AND MAXIMUM DRAIN TO SOURCE VOLTAGE 50.0
CURRENT RATING PER CHARACTERISTICMILLIAMPERES MAXIMUM GATE CURRENT 10.00
POWER RATING PER CHARACTERISTICMILLIWATTS MAXIMUM TOTAL DEVICE DISSIPATION 300.0
MAXIMUM OPERATING TEMP PER MEASUREMENT POINTCELSIUS JUNCTION 125.0
MATERIALENCLOSURE PLASTIC
TEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 80009-151-1005-00
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 3

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
VK01VK01-NOV-24VK81VK
WG01WG01-OCT-17WG81WG
YA01YA01-JAN-02YA81YA
YB01YB01-APR-91YB81YB
YD01YD01-MAR-17YD81YD
YS01YS01-FEB-15YS81YS
ZB01ZB01-APR-91ZB81ZB
ZC01ZC01-APR-91ZC81ZC
ZF01ZF01-APR-91ZF81ZF
ZJ01ZJ01-MAR-25ZJ81ZJ
ZP01ZP01-APR-91ZP81ZP
ZN01ZN01-APR-91ZN81ZN
ZR01ZR01-JUL-97ZR81ZR
ZU01ZU01-MAR-08ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
A918DA3C01-AUG-06ZCDGX01CD5DCD GXCL BDA196
FXGXDF3C01-AUG-06ZSXGX01SX5DGX TUFXTX
G860T10001-APR-91C864875 86
MC49DM3C01-AUG-06ZPAGX01PA5DGX PAMC13
N9BNDN3C01-AUG-06ZGHGX01GH5DGXHS KE HD GTN9ND
S911DG3C01-AUG-06ZXNGX01XN5DXN GXS007

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2
MIC
B

Freight

ACTY CD
98
NMFC
063025
NMFC sub
Z
Uniform freight class
34525
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
SEMICONDUCTORS/DEVICES NOI ETC

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
N CHANNEL FET

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
01-FEB-1989
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59615961-01-012-4942702-JUL-2026A
59615961-01-025-2644702-JUL-2026A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.