Catalog item

TRANSISTOR

5961FSC
00NCB code
722-1266Item number
NIIN 00-722-1266
Request a quote
Unit price
$518.04
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
20588
PINC
0020588
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-61
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8541500080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$518.041U0NSF9EH-V$0.00F
01-OCT-2026DNJSMSEA0.0000$518.041U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$518.041U0N-------$0.00I
01-OCT-2026GPJSMSEA0.0000$518.041U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
2N287621845
SOLITRON DEVICES, INC.
A593TX
2N287621921
RCA CORP DISTRIBUTOR AND SPECIAL PRODUCTS DIV
HC16ZZAC
2N287630043
SOLID STATE DEVICES, INC
A595TX3B
2N287634156
OSI OPTOELECTRONICS, INC DBA SEMICOA
A593TX3B
2N287634371
RENESAS ELECTRONICS AMERICA INC
A593TXB
299516653711
NAVAL SEA SYSTEMS COMMAND
AC16ZZAC
2N287654590
RCA CORP DISTRIBUTION AND SPECIAL PRODUCTS
H595TXB
2N287680131
ELECTRONIC INDUSTRIES ASSOCIATION
H393TX3D
RELEASE433080131
ELECTRONIC INDUSTRIES ASSOCIATION
H593TX3B
JAN2N287681349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC13ZZAC
2N2876AC7191
ADELCO ELEKTRONIK GMBH
R596ZG4B
2N2876C7191
ADELCO ELEKTRONIK GMBH
R596ZG4B
VBE890-2N2876H0203
THALES NEDERLAND
A523ZG3D
2N287612498
CRYSTALONICS, INC.
A323ZZ
2N287612954
MICROSEMI CORP.-SCOTTSDALE DBA MICROSEMI
H595TX3B
1125284317773
BALLISTIC MISSILE DEFENSE SYSTEMS COMMAND
H595TXB

Characteristics

THREAD SERIES DESIGNATORUNF
OVERALL DIAMETERINCHES MINIMUM 0.320 AND INCHES MAXIMUM 0.360
NOMINAL THREAD SIZEINCHES 0.190
CURRENT RATING PER CHARACTERISTICAMPERES MAXIMUM COLLECTOR CURRENT, DC 2.50
SEMICONDUCTOR MATERIALSILICON
VOLTAGE RATING IN VOLTS PER CHARACTERISTICMAXIMUM BREAKDOWN VOLTAGE, COLLECTOR-TO-BASE, EMITTER OPEN 80.0 AND MAXIMUM BREAKDOWN VOLTAGE, EMITTER-TO-BASE, COLLECTOR OPEN 4.0 AND MAXIMUM BREAKDOWN VOLTAGE, COLLECTOR-TO-EMITTER, BASE OPEN 60.0
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 3
OVERALL WIDTH ACROSS FLATSINCHES MINIMUM 0.424 AND INCHES MAXIMUM 0.437
MAXIMUM OPERATING TEMP PER MEASUREMENT POINTCELSIUS JUNCTION 200.0
SPECIAL FEATURESJUNCTION PATTERN ARRANGEMENT: NPN
INTERNAL CONFIGURATIONJUNCTION CONTACT
MOUNTING METHODTHREADED STUD(S)
OVERALL LENGTHINCHES MINIMUM 0.215 AND INCHES MAXIMUM 0.320
MOUNTING FACILITY QUANTITY1
POWER RATING PER CHARACTERISTICWATTS MAXIMUM COLLECTOR POWER DISSIPATION 18.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-JUN-11WP81WP
WG01WG01-OCT-17WG81WG
YA01YA01-SEP-00YA81YA
YB01YB01-APR-91YB81YB
YD01YD01-MAR-17YD81YD
ZC01ZC01-APR-91ZC81ZC
ZE01ZE01-APR-91ZE81ZE
ZH01ZH01-APR-91ZH81ZH
ZJ01ZJ01-MAR-25ZJ81ZJ
ZP01ZP01-APR-91ZP81ZP
ZS01ZS01-APR-91ZS81ZS
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
C911GP3Z01-AUG-06GX01XG5DXG GXC007
FXGXDF3Z01-AUG-06ZSXGX01SX5DGX TUFXTX
N9BNDN3Z01-AUG-06ZGHGX01GH5DGXHD GTN9ND
VJ01VJ01-FEB-19VJ81VJ

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
XX
NMFC
063025
NMFC sub
Z
Uniform freight class
34525
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
SEMICONDUCTORS/DEVICES NOI ETC

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
6
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
15-DEC-1974
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59615961-00-152-3755502-JUL-2026A
59615961-00-899-9902502-JUL-2026X

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.