Catalog item

TRANSISTOR

5961FSC
00NCB code
760-1116Item number
NIIN 00-760-1116
Request a quote
Unit price
$5.94
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
20588
PINC
0020588
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
07-APR-72
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8541500080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$5.941U0ZQ2200X-$0.00A
01-OCT-2026DFZSMSEA0.0000$5.941U0NSF9EH-V$0.00F
01-OCT-2026DNZSMSEA0.0000$5.941U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$5.941U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
6574234371
RENESAS ELECTRONICS AMERICA INC
A595TXB
537683-134371
RENESAS ELECTRONICS AMERICA INC
A595TXB
10100580A50423
BALLANTINE LABORATORIES INC
AC16ZZAC
1711817-149671
LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN DIV LOCKHEED MARTIN
H5929Z1B
4067349671
LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN DIV LOCKHEED MARTIN
HC15ZZAC
A310081535
AERONAUTICAL COMMUNICATIONS EQUIPMENT INC
H595481B
537683-196214
RAYTHEON COMPANY DBA RAYTHEON
A321TX3D
AM2040859D0894
ROHDE & SCHWARZ GMBH & CO. KOMMANDITGESELLSCHAFT DBA R & S
A523ZG4A
505-116D8008
PLATH GMBH & CO. KG
A521ZG3D
5800583-942200-104C0426
HENSOLDT SENSORS GMBH
A524ZG3D
SK00044H0203
THALES NEDERLAND
A521ZG4D
10140206811
EMCORE LLC DIV CONCORD DIVISION
A525TX4D
Q029706811
EMCORE LLC DIV CONCORD DIVISION
A595483B
48044011-4067306994
OCEAN APPLIED RESEARCH CORP
H59448
04474500012338
RIIMIC, LLC DBA SUNAIR ELECTRONICS
A595TXB
044745000012338
RIIMIC, LLC DBA SUNAIR ELECTRONICS
A525TX

Characteristics

SEMICONDUCTOR MATERIALSILICON
VOLTAGE RATING IN VOLTS PER CHARACTERISTICMAXIMUM GATE TO SOURCE CUTOFF VOLTAGE 6.0 AND MAXIMUM DRAIN TO SOURCE VOLTAGE 20.0 AND MAXIMUM DRAIN TO GATE VOLTAGE 20.0
CURRENT RATING PER CHARACTERISTICMILLIAMPERES MAXIMUM DRAIN CURRENT 50.00
TERMINAL LENGTHINCHES MINIMUM 0.500
MOUNTING METHODTERMINAL
TERMINAL CIRCLE DIAMETERINCHES NOMINAL 0.100
FEATURES PROVIDEDHERMETICALLY SEALED CASE
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 4
OVERALL LENGTHINCHES MINIMUM 0.170 AND INCHES MAXIMUM 0.210
OVERALL DIAMETERINCHES MINIMUM 0.209 AND INCHES MAXIMUM 0.230
INTERNAL CONFIGURATIONFIELD EFFECT
MAXIMUM OPERATING TEMP PER MEASUREMENT POINTCELSIUS JUNCTION 175.0
POWER RATING PER CHARACTERISTICMILLIWATTS MAXIMUM TOTAL POWER DISSIPATION 330.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
VP01VP01-DEC-24VP81VP
YA01YA01-JAN-02YA81YA
YB01YB01-APR-91YB81YB
YD01YD01-JUN-24YD81YD
YW01YW01-APR-91YW81YW
ZC01ZC01-APR-91ZC81ZC
ZG01ZG01-APR-91ZG81ZG
ZF01ZF01-APR-91ZF81ZF
ZH01ZH01-APR-91ZH81ZH
ZJ01ZJ01-MAR-25ZJ81ZJ
ZP01ZP01-APR-91ZP81ZP
ZR01ZR01-APR-91ZR81ZR
ZS01ZS01-APR-91ZS81ZS
ZT01ZT01-APR-91ZT81ZT
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
A918DA1C01-AUG-06ZCDGX01CD5DCD GXBD CLA196
BGX1GE1C01-JUL-07GX01485DGX 48
FXGXDF1C01-AUG-06ZSXGX01SX5DGX TUFXTX
G280T10001-APR-91C284828 75
N9BNDN1C01-AUG-06ZGHGX01GH5DGXHD JB KE GTN9ND
S911DG1C01-AUG-06ZXNGX01XN5DXN GXS007

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
TX
NMFC
063025
NMFC sub
Z
Uniform freight class
34525
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
SEMICONDUCTORS/DEVICES NOI ETC

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
01-DEC-1974
NIIN status code
0

Cancelled and replaced NIINs

FSC
5961
Cancelled NIIN
5961-00-403-2498
NIIN status code
7
Effective date
02-JUL-2026
DEMIL code
A

Request a quote