Catalog item

TRANSISTOR

5961FSC
00NCB code
812-1693Item number
NIIN 00-812-1693
Request a quote
Unit price
$256.19
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
20588
PINC
0020588
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
01-JAN-62
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8541500080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAXSMSEA0.0000$256.191U0ZQ2200X-$0.00A
01-OCT-2026DFVSMSEA0.0000$256.191U0NSF9EH-V$0.00F
01-OCT-2026DMZSMSEA0.0000$256.191U0Z15B2---$0.00M
01-OCT-2026DNXSMSEA0.0000$256.191U09B-----$0.00N
01-OCT-2026DSXSMSEA0.0000$256.191U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
JAN2N117481349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX4D
MIL-S-19500/21581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
2N117481349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC16ZZAC

Characteristics

SEMICONDUCTOR MATERIALGERMANIUM
CURRENT RATING PER CHARACTERISTICMILLIAMPERES MAXIMUM COLLECTOR CURRENT, DC -200.00 AND MILLIAMPERES MAXIMUM EMITTER CURRENT, DC 200.00
POWER RATING PER CHARACTERISTICMILLIWATTS MAXIMUM COLLECTOR POWER DISSIPATION 25.0
SPECIAL FEATURESJUNCTION PATTERN ARRANGEMENT: NPN
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-S-19500
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 3
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-S-19500 TO 215
MOUNTING METHODTERMINAL
TERMINAL CIRCLE DIAMETERINCHES NOMINAL 0.100
FEATURES PROVIDEDHERMETICALLY SEALED CASE
OVERALL DIAMETERINCHES MAXIMUM 0.370
VOLTAGE RATING IN VOLTS PER CHARACTERISTICMAXIMUM COLLECTOR TO BASE VOLTAGE/STATIC/EMITTER OPEN -35.0 AND MAXIMUM COLLECTOR TO EMITTER VOLTAGE/STATIC/BASE OPEN -20.0 AND MAXIMUM EMITTER TO BASE VOLTAGE, STATIC, COLLECTOR OPEN -35.0 AND MAXIMUM BREAKDOWN VOLTAGE, COLLECTOR TO EMITTER, WITH SPECIFIED VOLTAGE BETWEEN BASE AND EMITTER -35.0
INTERNAL CONFIGURATIONJUNCTION CONTACT
TERMINAL LENGTHINCHES MINIMUM 1.500
OVERALL LENGTHINCHES MAXIMUM 0.360

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-JAN-02YA81YA
ZR01ZR01-JUL-97ZR81ZR
ZW01ZW01-NOV-98ZW81ZW
A918DA3C01-AUG-06ZCDGX01CD5DCD GXA196
FXGXDF3C01-AUG-06ZSXGX01SX5DGX TUFXTX
MC49DM3C01-AUG-06ZPAGX01PA5DGX PAMC13
N9BNDN3C01-AUG-06ZGHGX01GH5DGXHD GTNIND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2

Freight

ACTY CD
XX
NMFC
063025
NMFC sub
Z
Uniform freight class
34525
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
SEMICONDUCTORS/DEVICES NOI ETC

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
HARDNESS CRITICAL ITEM (HC

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
96
Dt stdzn dec
01-JAN-1996
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.