Catalog item

SEMICONDUCTOR DEVICE,THYRISTOR

5961FSC
01NCB code
159-7157Item number
NIIN 01-159-7157
Request a quote
Unit price
$3.21
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
33096
PINC
0033096
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
13-AUG-83
Precious metals indicator
A
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8541300080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$3.211U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$3.211U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACSADC
2N634604713
FREESCALE SEMICONDUCTOR, INC.
A596TX
Q2010L413499
ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS
AC16ZZAC
353-6574-08013499
ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS
A396TX

Characteristics

OVERALL LENGTHINCHES MAXIMUM 0.185
TERMINAL LENGTHINCHES MINIMUM 1.320
OVERALL DIAMETERINCHES MAXIMUM 0.430
INTERNAL CONFIGURATIONJUNCTION CONTACT
MOUNTING METHODTERMINAL
TERMINAL CIRCLE DIAMETERINCHES NOMINAL 0.200
FEATURES PROVIDEDHERMETICALLY SEALED CASE
SEMICONDUCTOR MATERIALSILICON
VOLTAGE RATING IN VOLTS PER CHARACTERISTICMAXIMUM PEAK GATE VOLTAGE 200.0
CURRENT RATING PER CHARACTERISTICAMPERES MAXIMUM FORWARD CURRENT, REPETITIVE, MAXIMUM PEAK TOTAL VALUE 2.00
MAXIMUM OPERATING TEMP PER MEASUREMENT POINTCELSIUS JUNCTION 100.0
SPECIAL FEATURESJUNCTION PATTERN ARRANGEMENT: PNPNP
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 3

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
YB01YB01-OCT-96YB81YB
ZH01ZH01-APR-91ZH81ZH
FXGXDF3H01-AUG-06ZSXGX01SX5DGX TUFXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
063025
NMFC sub
Z
Uniform freight class
34525
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
SEMICONDUCTORS/DEVICES NOI ETC

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
13-AUG-1983
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.