Catalog item
Request a quoteTRANSISTOR
5961FSC
01NCB code
164-5104Item number
NIIN 01-164-5104
- Unit price
- $160.74
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 20588
- PINC
- 0020588
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 19-OCT-83
- Precious metals indicator
- A
- Hazardous material indicator
- N
- ESD/EMI code
- B
- Schedule B export code
- 8541590080
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DA | D | SMS | EA | 0.0000 | $160.74 | 1 | U | 0 | Z | Q2200X- | $0.00 | A |
| 01-OCT-2026 | DF | D | SMS | EA | 0.0000 | $160.74 | 1 | U | 0 | N | SF9EH-N | $0.00 | F |
| 01-OCT-2026 | DN | D | SMS | EA | 0.0000 | $160.74 | 1 | U | 0 | 9B----- | $0.00 | N | |
| 01-OCT-2026 | DS | D | SMS | EA | 0.0000 | $160.74 | 1 | U | 0 | N | ------- | $0.00 | I |
| 01-OCT-2026 | GP | D | SMS | EA | 0.0000 | $160.74 | 1 | U | 0 | ------- | $0.00 | C |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|---|
| SB8028-00 | 32760 THOMSON INC DIV GRASS VALLEY | A | C | 1 | 6 | ZZ | AC | ||
| MIL-PRF-19500/453 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 4 | 1 | 4 | ZZ | |||
| MIL-S-19500/453 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 5 | 9 | E | TX | B | ||
| 2N5109 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | C | 1 | 6 | ZZ | AC | ||
| JANTXV2N5109 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 2 | 2 | E | TX | |||
| JANTX2N5109 | 81350 JOINT ARMY-NAVY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | C | 1 | 6 | ZZ | AC | ||
| 81-271 | 88869 EATON CORP ELECTRONIC INSTRUMENTATION DIV LOS ANGELES PLANT | H | C | 1 | 6 | ZZ | AC | ||
| 3505009-001 | 92755 NORTHROP GRUMMAN SYSTEMS CORP DBA NORTHROP GRUMMAN SYSTEMS CORP | A | C | 1 | 6 | ZZ | AC | ||
| 5961PL1389501 | 9009H JEDNOLITY INDEKS MATERIALOWY - UNIFORM MATERIAL INDEX | A | 6 | 9 | 9 | WP | 4 | B | |
| 352-0863-011 | 95105 ROCKWELL COLLINS, INC. DIV COLLINS AEROSPACE - MISSION SYSTEMS | A | E | 8 | 2 | ZZ | |||
| 352-8011-230 | 94987 CUBIC DEFENSE APPLICATIONS, INC. | A | C | 1 | 6 | ZZ | AC | ||
| JAN2N5109 | 03538 LOCKHEED MARTIN CORPORATION DIV RMS | A | C | 1 | 6 | ZZ | AC | ||
| 663-00109 | 13488 DATRON THE INSTRUMENTS INC | H | E | 8 | 5 | 9Z | 4 | D | |
| 352-0863-011 | 13499 ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS | A | E | 8 | 2 | ZZ | 4 | D | |
| 352-0766-013 | 13499 ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS | A | C | 1 | 6 | ZZ | AC |
Characteristics
| OVERALL LENGTH | INCHES MAXIMUM 0.260 |
|---|---|
| TERMINAL LENGTH | INCHES MINIMUM 0.500 |
| OVERALL DIAMETER | INCHES MAXIMUM 0.370 |
| INTERNAL CONFIGURATION | JUNCTION CONTACT |
| JOINT ELECTRONIC DEVICE ENGINEERING COUNCIL/JEDEC/CASE OUTLINE DESIGNATION | TO-39 |
| MOUNTING METHOD | TERMINAL |
| TERMINAL CIRCLE DIAMETER | INCHES MAXIMUM 0.210 |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| SEMICONDUCTOR MATERIAL | SILICON |
| VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | MAXIMUM COLLECTOR TO BASE VOLTAGE/STATIC/EMITTER OPEN 40.0 AND MAXIMUM EMITTER TO BASE VOLTAGE, STATIC, COLLECTOR OPEN 3.0 AND MAXIMUM COLLECTOR TO EMITTER VOLTAGE/STATIC/BASE OPEN 20.0 |
| CURRENT RATING PER CHARACTERISTIC | AMPERES MAXIMUM COLLECTOR CURRENT, DC 0.40 |
| POWER RATING PER CHARACTERISTIC | WATTS MAXIMUM TOTAL POWER DISSIPATION 1.0 |
| TRANSFER RATIO | MAXIMUM STATIC FORWARD CURRENT TRANSFER RATIO, COMMON-EMITTER 120.0 |
| MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | CELSIUS AMBIENT AIR 200.0 |
| SPECIAL FEATURES | JUNCTION PATTERN ARRANGEMENT: NPN |
| TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-S-19500 |
| TERMINAL TYPE AND QUANTITY | UNINSULATED WIRE LEAD 3 |
| SPECIFICATION/STANDARD DATA | GOVERNMENT SPECIFICATION 81349--IL-S-19500 TO 453 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WP01 | WP | 01-APR-04 | WP | 81 | WP | ||||||||
| YA01 | YA | 01-DEC-01 | YA | 81 | YA | ||||||||
| YB01 | YB | 01-APR-91 | YB | 81 | YB | ||||||||
| YC01 | YC | 01-JUL-15 | YC | 81 | YC | ||||||||
| YD01 | YD | 01-APR-17 | YD | 81 | YD | ||||||||
| YW01 | YW | 01-JUL-17 | YW | 81 | YW | ||||||||
| ZG01 | ZG | 01-FEB-05 | ZG | 81 | ZG | ||||||||
| ZH01 | ZH | 01-MAY-03 | ZH | 81 | ZH | ||||||||
| ZJ01 | ZJ | 01-APR-25 | ZJ | 81 | ZJ | ||||||||
| ZN01 | ZN | 01-OCT-99 | ZN | 81 | ZN | ||||||||
| ZR01 | ZR | 01-OCT-06 | ZR | 81 | ZR | ||||||||
| ZU01 | ZU | 01-MAY-08 | ZU | 81 | ZU | ||||||||
| ZS01 | ZS | 01-JUL-15 | ZS | 81 | ZS | ||||||||
| ZW01 | ZW | 01-DEC-05 | ZW | 81 | ZW | ||||||||
| ZX01 | ZX | 01-APR-14 | ZX | 81 | |||||||||
| A918 | DA | 1 | T | 01-AUG-06 | Z | CD | GX | 01 | CD | 5D | CD GX | CT CL BD | A196 |
| BGX1 | GE | 1 | T | 01-AUG-06 | GX | 01 | 48 | 5D | GX 48 | BTX1 | |||
| C911 | GP | 1 | T | 01-AUG-06 | GX | 01 | XG | 5D | XG GX | C007 | |||
| FXGX | DF | 1 | T | 01-AUG-06 | Z | SX | GX | 01 | SX | 5D | GX TU | FXTX | |
| N9BN | DN | 1 | T | 01-AUG-06 | Z | HD | GX | 01 | GH | 5D | GX | HD KE HS GT | N9ND |
| S911 | DG | 1 | T | 01-AUG-06 | Z | XN | GX | 01 | XN | 5D | XN GX | S007 |
Service data
Army
- Matcat 1
- Q
- Matcat 2
- 2
- Matcat 3
- 2
- Matcat 4 5
- 00
- ARC
- X
Navy
- COG
- 9B
Air Force
- Fund
- SF
- Budget
- 9
- MMAC
- EH
- PVC
- N
- ERRC
- N
Freight
- ACTY CD
- TX
- NMFC
- 063025
- NMFC sub
- Z
- Uniform freight class
- 34525
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- 3
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- SEMICONDUCTORS/DEVICES NOI ETC
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69Z0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- 100100 unit packs per intermediate container
- Method of preservation
- GXPreserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- NBA-A-3129, Type I, Grade B, static dissipative open cell plastic cushioning.
- THK
- A1/4 inch thick
- Unit cont
- B9MIL-DTL-117, Type I, Class F, Style 1, heavy duty, watervaporproof, electrostatic protective, opaque bag.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- E5ASTM D5118/D5118M, fiberboard box.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- UItems or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
- Unit pack weight
- 0.1000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0010
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- CLASS 1 ESD
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 88090
Related items
Standardization
| Related NSN | Item standardization code | Orig stdzn dec | Dt stdzn dec | NIIN status code |
|---|---|---|---|---|
| 5961-01-446-2792 | 3 | TX | 18-FEB-2009 | 0 |
| 5961-00-139-2397 | 3 | TX | 18-FEB-2009 | 0 |
| 5961-00-603-8935 | 3 | TX | 12-NOV-1997 | 0 |
| 5961-00-252-1331 | 3 | TX | 12-NOV-1997 | 0 |
| 5961-01-061-3412 | 3 | TX | 03-MAR-2015 | 0 |
| 5961-01-419-6535 | 3 | TX | 18-FEB-2009 | 6 |
| 5961-00-594-3020 | 3 | TX | 18-FEB-2009 | 0 |
| 5961-00-494-4936 | 3 | TX | 12-NOV-1997 | 0 |
| 5961-01-027-7571 | 3 | TX | 12-NOV-1997 | 0 |
| 5961-00-412-0650 | 3 | TX | 12-NOV-1997 | 0 |
| 1 | TX | 12-NOV-1997 | 0 | |
| 3 | TX | 18-FEB-2009 | 0 | |
| 3 | TX | 03-MAR-2015 | 0 | |
| 3 | TX | 12-NOV-1997 | 0 |
Cancelled and replaced NIINs
| FSC | Cancelled NIIN | NIIN status code | Effective date | DEMIL code |
|---|---|---|---|---|
| 5961 | 5961-01-070-4728 | 5 | 22-JUL-2026 | A |
| 5961 | 5961-01-042-8634 | 5 | 22-JUL-2026 | B |
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.