Catalog item

MICROCIRCUIT,LINEAR

5962FSC
00NCB code
900-8132Item number
NIIN 00-900-8132
Request a quote
Unit price
$589.97
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
31778
PINC
0031778
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
15-APR-68
Precious metals indicator
G
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8542900000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$589.971U0AQ2200X-$0.00A
01-OCT-2026DFZSMSEA0.0000$589.971U0NSF9EH-V$0.00F
01-OCT-2026DNZSMSEA0.0000$589.971U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$589.971U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
57502901933A
ELTA SYSTEMS LTD
A525TX
B50100100223223
CTS MICROELECTRONICS
H595KE3B
CT-74132116
MARCONI CIRCUIT TECHNOLOGY CORP MICROELECTRONICS DIV
H596TXB
NCS96350821
CRANE ELECTRONICS INC
A525TX
11503790-188818
KEARFOTT CORPORATION DIV GUIDANCE AND NAVIGATION DIVISION
AE86BD
B50100100288818
KEARFOTT CORPORATION DIV GUIDANCE AND NAVIGATION DIVISION
A321KE1A
575-0290S0131
ELTA SYSTEMS LTD
R596TX4B
5750290S0131
ELTA SYSTEMS LTD
R596TX4B
B50100100214936
GENERAL SEMICONDUCTOR INC
A595TX3B
B50100100215818
TELCOM SEMICONDUCTOR INC
H595KE3D
11503790-118876
US ARMY AVIATION AND MISSILE COMMAND
AE81BD

Characteristics

INCLOSURE CONFIGURATIONSINGLE-IN-LINE
INPUT CIRCUIT PATTERN5 CHANNEL
TERMINAL SURFACE TREATMENTGOLD
INCLOSURE MATERIALCERAMIC AND GLASS
FEATURES PROVIDEDHERMETICALLY SEALED AND HYBRID AND POSITIVE OUTPUTS
VOLTAGE RATING AND TYPE PER CHARACTERISTICVOLTS MAXIMUM POWER SOURCE 7.0
BODY LENGTHINCHES MINIMUM 0.610 AND INCHES MAXIMUM 0.640
BODY WIDTHINCHES MINIMUM 0.610 AND INCHES MAXIMUM 0.640
OPERATING TEMP RANGECELSIUS -55.0 TO 105.0
PRECIOUS MATERIAL AND LOCATIONGOLD TER-INAL SURFACE
PRECIOUS MATERIALGOLD
TEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 88818-8501001002
TERMINAL TYPE AND QUANTITYPIN 11
BODY HEIGHTINCHES MAXIMUM 0.150
STORAGE TEMP RANGECELSIUS -65.0 TO 150.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZU01ZU01-APR-08ZU81ZU
A918DA1H01-AUG-06ZCDGX01CD5DCD GXA196
FXGXDF1H01-AUG-06ZSXGX01SX5DGX TUFXTX
N9BNDN1H01-AUG-06ZKEGX01GH5DGXKEN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
KE
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
6
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0100
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
GX
Dt stdzn dec
01-JUN-2007
NIIN status code
0

Cancelled and replaced NIINs

FSC
5962
Cancelled NIIN
5962-01-167-4711
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
B

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.