Catalog item

MICROCIRCUIT,MEMORY

5962FSC
01NCB code
194-4209Item number
NIIN 01-194-4209
Request a quote
Unit price
$68.11
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
41015
PINC
0041015
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
14-NOV-84
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8542900000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$68.11170ZQ22CCX-$0.00A
01-OCT-2026DFZSMSEA0.0000$68.11170NSF9EH-N$0.00F
01-OCT-2026DNZSMSEA0.0000$68.111709B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$68.11170N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSCSADC
704AS556630003
NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
A325TX
65S05932293
INTERSIL INC SUB OF GENERAL ELECTRIC CO
HC16ZZAC
HMI-6508B-834371
RENESAS ELECTRONICS AMERICA INC
AC11ZZAC
IM6508AMJE/883B32293
INTERSIL INC SUB OF GENERAL ELECTRIC CO
HC16ZZAC
HM1-6508B-834371
RENESAS ELECTRONICS AMERICA INC
A59ETXB
IM6508-MDE32293
INTERSIL INC SUB OF GENERAL ELECTRIC CO
H59ETXB

Characteristics

BODY LENGTHINCHES MAXIMUM 0.785
BODY WIDTHINCHES MINIMUM 0.295 AND INCHES MAXIMUM 0.305
BODY HEIGHTINCHES MAXIMUM 0.170
MAXIMUM POWER DISSIPATION RATINGMILLIWATTS 1.0
OPERATING TEMP RANGECELSIUS -55.0 TO 125.0
STORAGE TEMP RANGECELSIUS -65.0 TO 150.0
FEATURES PROVIDEDBURN IN AND COMPATIBLE CMOS AND 3-STATE OUTPUT
INCLOSURE MATERIALCERAMIC
INCLOSURE CONFIGURATIONDUAL-IN-LINE
OUTPUT LOGIC FORMTRANSISTOR-TRANSISTOR LOGIC
INPUT CIRCUIT PATTERN13 INPUT
TERMINAL SURFACE TREATMENTSOLDER
VOLTAGE RATING AND TYPE PER CHARACTERISTICVOLTS MAXIMUM POWER SOURCE 7.0
MEMORY DEVICE TYPEROM
TEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 30003-704AS5566
TERMINAL TYPE AND QUANTITYPRINTED CIRCUIT 16

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YB01YB01-MAY-97YB81YB
ZC01ZC01-APR-91ZC81ZC
ZE01ZE01-APR-00ZE81ZE
ZG01ZG01-APR-91ZG81ZG
ZU01ZU01-MAY-08ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
A918DA3C01-AUG-06ZCDGX01CD5DCD GXBFA196
FXGXDF3C01-AUG-06ZSXGX01SX5DGX TUFXTX
N9BNDN3C01-AUG-06ZKEGX01GH5DGXHD KE GTN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
CC
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
16337

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
5962-01-189-25073TX23-AUG-19940
5962-01-097-38993TX28-JUL-19880
5962-01-178-43893TX06-MAR-20050
5962-01-134-71903TX23-AUG-19940
5962-01-065-14613TX06-FEB-19910
3TX23-AUG-19940
1TX06-FEB-19910
3TX06-MAR-20050
3TX28-JUL-19880
3TX06-FEB-19910

Cancelled and replaced NIINs

FSC
5962
Cancelled NIIN
5962-01-139-1526
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
Q

Request a quote