Catalog item

MICROCIRCUIT,LINEAR

5962FSC
01NCB code
237-9845Item number
NIIN 01-237-9845
Request a quote
Unit price
$32.54
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
31778
PINC
0031778
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
08-AUG-86
Precious metals indicator
G
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
D
Schedule B export code
8542900000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$32.54170AQ2200X-$0.00A
01-OCT-2026DFZSMSEA0.0000$32.54170NSF9EH-N$0.00F
01-OCT-2026DNZSMSEA0.0000$32.541709B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$32.54170N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
MIL-M-38510/11681349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX
JM38510/11601BIX81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AE83KE
M38510/11601BIC81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX

Characteristics

BODY OUTSIDE DIAMETERINCHES MINIMUM 0.335 AND INCHES MAXIMUM 0.370
BODY HEIGHTINCHES MINIMUM 0.165 AND INCHES MAXIMUM 0.185
MAXIMUM POWER DISSIPATION RATINGMILLIWATTS 350.0
OPERATING TEMP RANGECELSIUS -55.0 TO 125.0
STORAGE TEMP RANGECELSIUS -65.0 TO 150.0
FEATURES PROVIDEDHERMETICALLY SEALED AND MONOLITHIC AND NEGATIVE OUTPUTS AND POSITIVE OUTPUTS
INCLOSURE MATERIALMETAL
INCLOSURE CONFIGURATIONCAN
INPUT CIRCUIT PATTERN2 CHANNEL AND DUAL 1 INPUT
DESIGN FUNCTION AND QUANTITYSWITCH, ANALOG, SINGLE POLE SINGLE THROW NORMALLY CLOSED 2
CASE OUTLINE SOURCE AND DESIGNATORMIL-M-38510 A-2
TERMINAL SURFACE TREATMENTGOLD
PRECIOUS MATERIAL AND LOCATIONGOLD TER-INAL SURFACES
PRECIOUS MATERIALGOLD
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL---38510
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL---38510 TO 116

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-JUN-07WP81WP
A918DA1T01-AUG-06ZCTGX01CD5DCD GXCTA196
FXGXDF1T01-AUG-06ZSXGX01SX5DGX TUFXTX
N9BNDN1T01-AUG-06ZHDGX01GH5DGXKE GT HDN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
100
100 unit packs per intermediate container
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
E5
ASTM D5118/D5118M, fiberboard box.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
6
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0020
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
ESD AND PHYSICAL PROTECTIO

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
GX
Dt stdzn dec
01-NOV-2010
NIIN status code
0

Cancelled and replaced NIINs

FSC
5962
Cancelled NIIN
5962-01-552-9596
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
Q

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.