Catalog item

MICROCIRCUIT,DIGITAL

5962FSC
01NCB code
246-2933Item number
NIIN 01-246-2933
Request a quote
Unit price
$179.79
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
31779
PINC
0031779
Criticality code
H
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
11-DEC-86
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8542900000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFZSMSEA0.0000$179.791U0NSF9EH-N$0.00F
01-OCT-2026DNZSMSEA0.0000$179.791U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$179.791U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSCSADC
13201335-0227963
GENERAL DYNAMICS INFORMATION SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS
RC16ZZAC
166505-0335351
GE AVIATION SYSTEMS LLC
A32ATX
7907526-4690536
LOCKHEED MARTIN CORP DBA LOCKHEED MARTIN DIV MST - EAGAN
AC16ZZAC
77A10515P00103538
LOCKHEED MARTIN CORPORATION DIV RMS
AC15ZZAF
54F10M/B2CJC04713
FREESCALE SEMICONDUCTOR, INC.
A51ETX
54F10L1MQB07263
FAIRCHILD SEMICONDUCTOR CORP
A59ETX
54F10/B2C18324
PHILIPS SEMICONDUCTORS INC
H59ETXB

Characteristics

BODY LENGTHINCHES MAXIMUM 0.358
BODY WIDTHINCHES MAXIMUM 0.358
BODY HEIGHTINCHES MAXIMUM 0.100
MAXIMUM POWER DISSIPATION RATINGMILLIWATTS 42.0
OPERATING TEMP RANGECELSIUS -55.0 TO 125.0
STORAGE TEMP RANGECELSIUS -65.0 TO 150.0
FEATURES PROVIDEDELECTROSTATIC SENSITIVE AND HERMETICALLY SEALED AND BURN IN AND MONOLITHIC AND SCHOTTKY
INCLOSURE MATERIALCERAMIC
INCLOSURE CONFIGURATIONLEADLESS FLAT PACK
OUTPUT LOGIC FORMTRANSISTOR-TRANSISTOR LOGIC
INPUT CIRCUIT PATTERNTRIPLE 3 INPUT
DESIGN FUNCTION AND QUANTITYGATE, NAND 3
CASE OUTLINE SOURCE AND DESIGNATORMIL-M-38510 C-2
TERMINAL SURFACE TREATMENTSOLDER
VOLTAGE RATING AND TYPE PER CHARACTERISTICVOLTS MAXIMUM POWER SOURCE 7.0
TIME RATING PER CHACTERISTICNANOSECONDS MAXIMUM PROPAGATION DELAY TIME, LOW TO HIGH LEVEL OUTPUT 7.00 AND NANOSECONDS MAXIMUM PROPAGATION DELAY TIME, HIGH TO LOW LEVEL OUTPUT 6.50
SPECIAL FEATURESNUCLEAR HARDNESS CRITICAL ITEMS
NUCLEAR HARDNESS CRITICAL FEATUREHARDENED
TEST DATA DOCUMENTSTANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). 96906--IL-STD-883
TERMINAL TYPE AND QUANTITYLEADLESS 20

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-JUN-07WP81WP
YB01YB01-MAY-97YB81YB
ZF01ZF01-APR-00ZF81ZF
ZJ01ZJ01-APR-25ZJ81ZJ
ZW01ZW01-DEC-05ZW81ZW
FXGXDF1C01-AUG-06ZSXGX01SX5DGX TUFXTX
N9BNDN1C01-AUG-06ZHDGX01GH5DGXGT KE HDN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TH
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
11-DEC-1986
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.