Catalog item

MICROCIRCUIT,LINEAR

5962FSC
01NCB code
367-4587Item number
NIIN 01-367-4587
Request a quote
Unit price
$87.67
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
31778
PINC
0031778
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
12-NOV-92
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8542900000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DADSMSEA0.0000$87.671U0ZQ2200X-$0.00A
01-OCT-2026DFDSMSEA0.0000$87.671U0NSF9EH-N$0.00F
01-OCT-2026DNDSMSEA0.0000$87.671U09B-----$0.00N
01-OCT-2026DSDSMSEA0.0000$87.671U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
DS26C32AMJ/88327014
NATIONAL SEMICONDUCTOR CORPORATION
A51ETX
5962-9164067268
DLA WEAPONS SUPPORT (COLUMBUS) DIV DOCUMENT STANDARDIZATION DIVISION (VA)
A41ETX
5962-9164001MEX67268
DLA WEAPONS SUPPORT (COLUMBUS) DIV DOCUMENT STANDARDIZATION DIVISION (VA)
A59ETXB
5962-9164001MEA67268
DLA WEAPONS SUPPORT (COLUMBUS) DIV DOCUMENT STANDARDIZATION DIVISION (VA)
A22ETX
5962-9164001MEB67268
DLA WEAPONS SUPPORT (COLUMBUS) DIV DOCUMENT STANDARDIZATION DIVISION (VA)
A59ETXB
91672826F6481
THALES SA
A524ZF4B
301-005927U4338
THALES UK LIMITED DBA THALES UK LTD DEFENCE MISSION SYSTEMS
A524ZK1D

Characteristics

MAXIMUM POWER DISSIPATION RATINGMILLIWATTS 1500.0
OPERATING TEMP RANGECELSIUS -55.0 TO 125.0
STORAGE TEMP RANGECELSIUS -65.0 TO 150.0
END ITEM IDENTIFICATION4920010415862 E/I FSCM 65552; MULTIPLE LAUNCH ROCKET SYSTEM (MLRS)
FEATURES PROVIDEDMONOLITHIC
INCLOSURE MATERIALCERAMIC
INCLOSURE CONFIGURATIONDUAL-IN-LINE
INPUT CIRCUIT PATTERN4 WIDE 2 INPUT
DESIGN FUNCTION AND QUANTITYRECEIVER, LINE DIFFERENTIAL 4
CASE OUTLINE SOURCE AND DESIGNATORMIL-M-38510 D-2
CURRENT RATING PER CHARACTERISTICMILLIAMPERES MINIMUM OUTPUT -25.00 AND MILLIAMPERES MAXIMUM OUTPUT 25.00
TERMINAL SURFACE TREATMENTSOLDER
PART NAME ASSIGNED BY CONTROLLING AGENCYMICROCIRCUIT,LINEAR,CMOS,QUAD DIFFERENTIAL LINE RECEIVER,MONOLITHIC SILICON
VOLTAGE RATING AND TYPE PER CHARACTERISTICVOLTS MINIMUM POSITIVE POWER SUPPLY SPAN 4.5 AND VOLTS MAXIMUM POSITIVE POWER SUPPLY SPAN 5.5
TEST DATA DOCUMENTSTANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). 96906--IL-STD-883 AND STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). 96906--IL-STD-480
TERMINAL TYPE AND QUANTITYPRINTED CIRCUIT 16
SPECIFICATION/STANDARD DATAGOVERNMENT STANDARD 67268-5962-91640 AND GOVERNMENT SPECIFICATION 81349--IL---38510 AND GOVERNMENT SPECIFICATION 81349--IL-I-38535
NONDEFINITIVE SPEC/STD DATATYPE 01 AND CLASS - AND CASE E

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WG01WG01-OCT-17WG81WG
WP01WP01-JUN-11WP81WP
YA01YA01-DEC-01YA81YA
YB01YB01-APR-13YB81YB
ZG01ZG01-JAN-04ZG81ZG
ZH01ZH01-JUL-98ZH81ZH
ZJ01ZJ01-APR-25ZJ81ZJ
ZU01ZU01-MAY-08ZU81ZU
ZW01ZW01-SEP-01ZW81ZW
ZX01ZX01-FEB-14ZX81
A918DA1T01-AUG-06ZCTGX01CD5DCD GXBD CT AZA196
FXGXDF1T01-AUG-06ZSXGX01SX5DGX TUFXTX
N9BNDN1T01-AUG-06ZKEGX01GH5DGXKE GT HDN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TH
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0100
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
1TX29-AUG-20230
3TX29-AUG-20230
5962-01-421-89683TX29-AUG-20230

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.