Catalog item

ELECTRONIC MODULE,STANDARDIZED

5963FSC
00NCB code
413-2624Item number
NIIN 00-413-2624
Request a quote
Unit price
$14,618.98
Unit of issue
EA
Source of supply
SMS
DEMIL code
B

Identification

Item name code
36647
PINC
0036647
Criticality code
X
II
0
DEMIL code
B
DEMIL integrity code
3
NIIN assigned
25-JAN-72
Precious metals indicator
G
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8542900000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$14,618.981U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$14,618.981U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
318539960225
L3 TECHNOLOGIES, INC. DIV OCEAN SYSTEMS
A595TXB
332659860225
L3 TECHNOLOGIES, INC. DIV OCEAN SYSTEMS
A595TX
318509059364
HONEYWELL INTERNATIONAL INC. DBA HONEYWELL INTERNATIONAL
AC15ZZD9F
318509060225
L3 TECHNOLOGIES, INC. DIV OCEAN SYSTEMS
A595TXB
318509077068
ALLIED-SIGNAL INC DBA ALLIED-SIGNAL AEROSPACE CO ELECTRODYNAMICS DIV
R591KE3D
318539991342
AKZO NOBEL AEROSPACE COATINGS INC
A322ZZ
10172113856
CTS HALEX INC
H595TX1B
10170113856
CTS HALEX INC
H595KE3B

Characteristics

ENVIRONMENTAL PROTECTIONSALT SPRAY RESISTANT AND VIBRATION
OVERALL HEIGHTINCHES NOMINAL 0.290
SIGNAL DATA TYPE PER CHANNELOPERATING CHANNEL RANGE
OVERALL LENGTHINCHES NOMINAL 2.620
AVERAGE LIFE RATING500.0
STORAGE TEMP RANGECELSIUS -62.0 TO 125.0
AVERAGE LIFE MEASUREMENTHOURS
BASIC SHAPE STYLE
PRECIOUS MATERIAL AND LOCATIONGOLD EXTERNAL CASE
PRECIOUS MATERIALGOLD
TEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 77068-3185090
EXTERNAL DC OPERATING VOLTAGE IN VOLTSNOMINAL 1ST VOLTAGE -9.0 AND NOMINAL 2ND VOLTAGE 9.0
SPECIAL MARKINGSBANDPASS FILTER PAIR
OPERATING CONTROL METHODAUTOMATIC
OPERATING TEMP RANGECELSIUS 0.0 TO 60.0
OVERALL WIDTHINCHES NOMINAL 1.950
INSTALLATION DESIGNMODULE
CONTROL TYPEREMOTE
CONNECTION CONTACT TYPE AND QUANTITYPLUG CONNECTOR EXTERNAL 1
CONNECTION TYPEBOTTOM PLUG CONNECTOR
INCLOSURE TYPEENCASED
CIRCUIT CONSTRUCTION TYPESOLID STATE
MAXIMUM POWER DRAIN RATINGMILLIWATTS 1100.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-OCT-01YA81YA
YB01YB01-APR-91YB81YB
ZC01ZC01-APR-91ZC81ZC
ZG01ZG01-APR-91ZG81ZG
ZH01ZH01-APR-91ZH81ZH
ZP01ZP01-APR-91ZP81ZP
ZR01ZR01-JUL-97ZR81ZR
ZU01ZU01-AUG-05ZU81ZU
ZW01ZW01-DEC-05ZW81ZW
N9BNDN1B01-AUG-06ZKEGX01GH5DGXKEN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
KE
NMFC
061480
NMFC sub
X
Uniform freight class
34500
Less than truckload
P
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CONTROLLERS/PARTS NOI O/T PLASTIC

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
39
ESD sensitive electronic device requirements of MIL-STD-129 apply
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.3000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
ESD AND PHYSICAL PROTECTIO

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
C
Orig stdzn dec
TX
Dt stdzn dec
01-DEC-1974
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.