Catalog item

ELECTRONIC MODULE,STANDARDIZED

5963FSC
01NCB code
062-2196Item number
NIIN 01-062-2196
Request a quote
Unit price
$554.90
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
36647
PINC
0036647
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
13-JUL-78
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8542900000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DNYSMSEA0.0000$554.901U0D3BGL---$0.00N
01-OCT-2026DSYSMSEA0.0000$554.901U0F-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
M28787/197-11SNT7
NAVAL SURFACE WARFARE CENTER DBA PORT HUENEME DETACHENT VIRGINIA BEACH
A515ZZ
M28787/19781349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX4B
M28787/197-181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22ETX
MIL-M-28787/19781349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX4D

Characteristics

OVERALL LENGTHINCHES NOMINAL 2.620
OVERALL HEIGHTINCHES NOMINAL 0.290
OVERALL WIDTHINCHES NOMINAL 1.950
ENVIRONMENTAL PROTECTIONSALT SPRAY RESISTANT AND VIBRATION
OPERATING TEMP RANGECELSIUS 0.0 TO 60.0
AVERAGE LIFE RATING500.0
STORAGE TEMP RANGECELSIUS -62.0 TO 125.0
AVERAGE LIFE MEASUREMENTHOURS
BASIC SHAPE STYLE
INCLOSURE TYPEENCASED
OPERATING CONTROL METHODAUTOMATIC
INSTALLATION DESIGNMODULE
CONTROL TYPEREMOTE
CONNECTION TYPEBOTTOM PLUG CONNECTOR
CIRCUIT CONSTRUCTION TYPESOLID STATE
AVERAGE POWER RATING PER CHANNELMILLIWATTS OUTPUT 792.0 AND MILLIWATTS OUTPUT 842.0
SIGNAL VOLTAGE RATING PER CHANNELMILLIVOLTS MINIMUM INPUT -500.000 AND MILLIVOLTS MAXIMUM INPUT 800.000 AND VOLTS MINIMUM INPUT 2.000 AND VOLTS MAXIMUM INPUT 5.500 AND MILLIVOLTS MAXIMUM OUTPUT 400.000 AND MILLIVOLTS MAXIMUM OUTPUT 700.000
PULSE DURATION PER CHANNELNANOSECONDS NOMINAL OPERATING CHANNEL 500.000
PULSE RISE TIME PER CHANNELNANOSECONDS NOMINAL OPERATING CHANNEL 1000.000
PULSE PEAK AMPLITUDE PER CHANNELVOLTS OPERATING CHANNEL 3.500
SIGNAL DATA TYPE PER CHANNEL1ST INPUT CHANNEL DIGITAL AND 2ND INPUT CHANNEL DIGITAL AND 1ST OUTPUT CHANNEL DIGITAL AND 2ND OUTPUT CHANNEL DIGITAL
CONNECTION CONTACT TYPE AND QUANTITYPLUG CONNECTOR EXTERNAL 1
EXTERNAL DC OPERATING VOLTAGE IN VOLTSNOMINAL SINGLE VOLTAGE 5.0
SPECIAL FEATURESKEY CODE EBD
SPECIAL MARKINGSINVERTER
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL---28787
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL---28787 TO 197

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YB01YB01-OCT-03YB81YB
N9BNDN1C01-AUG-06ZGHGX01GH5DGXGT HD JV JBN9ND

Service data

Navy

COG
3B
SMIC
GL

Freight

ACTY CD
TX
NMFC
061480
NMFC sub
X
Uniform freight class
34500
Less than truckload
P
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CONTROLLERS/PARTS NOI O/T PLASTIC

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
Z
Special requirements – See specific instructions or drawings provided
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
39
ESD sensitive electronic device requirements of MIL-STD-129 apply
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0140
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
ESD AND PHYSICAL PROTECTIO

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
13-JUL-1978
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.