Catalog item
Request a quoteINSULATION SLEEVING,ELECTRICAL,S
5970FSC
01NCB code
084-2597Item number
NIIN 01-084-2597
- Unit price
- $117.35
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 61626
- PINC
- 0061626
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 13-OCT-79
- Precious metals indicator
- U
- Hazardous material indicator
- P
- Schedule B export code
- 8546900000
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DA | J | SMS | EA | 0.0000 | $117.35 | 1 | U | 0 | Z | Q2200X- | $0.00 | A |
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $117.35 | 1 | U | 0 | 9B----- | $0.00 | N | |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $117.35 | 1 | U | 0 | N | ------- | $0.00 | I |
Part numbers
Characteristics
| TEMP RATING | CELSIUS -55.0 |
|---|---|
| ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT |
| DISTANCE FROM CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | AFTER UNRESTRICTED RECOVERY INCHES MINIMUM 1.350 AND INCHES MAXIMUM 1.650 |
| MAIN BODY INSIDE DIAMETER | AS SUPPLIED INCHES MINIMUM 1.200 |
| MAIN BODY INSIDE DIAMETER | AFTER UNRESTRICTED RECOVERY INCHES MAXIMUM 0.600 |
| FIRST BRANCH INSIDE DIAMETER | AFTER UNRESTRICTED RECOVERY INCHES MAXIMUM 0.350 |
| FIRST BRANCH INSIDE DIAMETER | AS SUPPLIED INCHES MINIMUM 0.700 |
| MAIN BODY WALL THICKNESS | AS SUPPLIED INCHES NOMINAL 0.090 |
| MAIN BODY WALL THICKNESS | AFTER UNRESTRICTED RECOVERY INCHES NOMINAL 0.090 |
| FIRST BRANCH WALL THICKNESS | AFTER UNRESTRICTED RECOVERY INCHES MINIMUM 0.040 AND INCHES MAXIMUM 0.060 |
| FIRST BRANCH WALL THICKNESS | AS SUPPLIED INCHES NOMINAL 0.050 |
| MAIN BODY OVERALL LENGTH | AS SUPPLIED INCHES MINIMUM 3.170 |
| MAIN BODY OVERALL LENGTH | AFTER UNRESTRICTED RECOVERY INCHES MAXIMUM 3.200 |
| ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | AFTER UNRESTRICTED RECOVERY MINIMUM 85.0 AND MAXIMUM 95.0 |
| ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | AS SUPPLIED MINIMUM 5.0 AND MAXIMUM 25.0 |
| MINIMUM TENSILE STRENGTH | POUNDS PER SQUARE INCH 1200 |
| SPECIAL FEATURES | MAIN BODY ID 0.700 IN. MIN AS SUPPLIED,0.350 IN. MAX AFTER UNRETRICTED RECOVERY OPPOSITE END; WALL THK RAPERS TO 0.050 IN. NOMINAL AS SUPPLIED |
| FLEXIBILITY | FLEXIBLE |
| MATERIAL | LOCATION NOT OTHERWISE SPECIFIED PLASTIC POLYOLEFIN |
| MATERIAL DOCUMENT AND CLASSIFICATION | LOCATION NOT OTHERWISE SPECIFIED MFR REF SINGLE MATERIAL RESPONSE RT-1304,RAYCHE- COR |
| STYLE DESIGNATOR | |
| DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | VOLTS PER MIL /0.001 INCH/ 200.0 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZU01 | ZU | 01-APR-06 | ZU | 81 | ZU | ||||||||
| ZX01 | ZX | 01-APR-91 | ZX | 81 | |||||||||
| A918 | DA | 3 | L | 01-DEC-04 | Z | CD | GX | 01 | CD | 5D | CD GX | BD | A917 |
| N9BG | DN | 3 | L | 01-SEP-04 | Z | GH | GX | 01 | GH | 5D | GX |
Service data
Army
- Matcat 1
- Q
- Matcat 2
- 2
- Matcat 3
- 2
- Matcat 4 5
- 00
- ARC
- X
Navy
- COG
- 9B
Freight
- ACTY CD
- BF
- NMFC
- 103300
- NMFC sub
- Z
- Uniform freight class
- 53360
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- INSULATING MATERIAL NOI
Packaging
Unit and preservation
- PICA SICA
- P
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 10Physical protection
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- A1Bags made of material conforming to MIL-P-130, or any bag authorized by MIL-DTL-117.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- Lvl A
- EPacking shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
- Supplemental instructions
- IP025: PACKAGING, MARKING,
Packaging instructions
- PICA SICA
- P
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 2
- Orig stdzn dec
- CX
- Dt stdzn dec
- 27-JUL-1980
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.