Catalog item
Request a quoteCOUPLER,OPTOELECTRONIC
5980FSC
01NCB code
249-9196Item number
NIIN 01-249-9196
- Unit price
- $82.81
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- Q
Identification
- Item name code
- 62335
- PINC
- 0062335
- Criticality code
- X
- II
- 0
- DEMIL code
- Q
- DEMIL integrity code
- 3
- NIIN assigned
- 20-FEB-87
- Precious metals indicator
- A
- Hazardous material indicator
- N
- ESD/EMI code
- B
- Schedule B export code
- 8541409500
- FedMall
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DF | J | SMS | EA | 0.0000 | $82.81 | 1 | U | 0 | N | SF9EH-N | $0.00 | F |
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $82.81 | 1 | U | 0 | 9B----- | $0.00 | N | |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $82.81 | 1 | U | 0 | N | ------- | $0.00 | I |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNSC |
|---|---|---|---|---|---|---|---|
| JANTXV4N47 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 2 | 2 | E | TX | |
| MIL-S-19500/548 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 5 | 9 | E | TX | B |
| MIL-PRF-19500/548 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 4 | 1 | 4 | ZZ |
Characteristics
| STORAGE TEMP RANGE | CELSIUS -65.0 TO 125.0 |
|---|---|
| TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-S-19500 |
| GENERAL CHARACTERISTICS ITEM DESCRIPTION | COUPLER OPTO-ELECTRONIC SOLID STATE; VCB0 45.0 VOLTS DC; IC 50.0 MA DC; PT POWER DISSIPATION 300.0 MW; TJ OPERATING TEMPERATURE RANGE FROM MINUS 65.0 TO PLUS 125.0 DEGREE CELSIUS; 0.185 IN. MAX LG; 0.370 IN. MAX DIA; SIX WIRE TERMINALS 0.600 IN. MAX LG |
| SPECIFICATION/STANDARD DATA | GOVERNMENT SPECIFICATION 81349--IL-S-19500 TO 548 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FXGX | DF | 1 | T | 01-AUG-06 | Z | SX | GX | 01 | SX | 5D | GX TU | FXTX | |
| N9BN | DN | 1 | T | 01-AUG-06 | Z | KE | GX | 01 | GH | 5D | GX | KE GT | N9ND |
Service data
Navy
- COG
- 9B
Air Force
- Fund
- SF
- Budget
- 9
- MMAC
- EH
- PVC
- N
- ERRC
- N
Freight
- ACTY CD
- TH
- NMFC
- 061680
- NMFC sub
- Z
- Uniform freight class
- 34570
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- 3
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC WIRING PLUGS ETC
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- GXPreserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 39ESD sensitive electronic device requirements of MIL-STD-129 apply
- Inter cont
- DOAny suitable fiber box included in this table may be used (see J.4.9.1).
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- UItems or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
- Unit pack weight
- 0.1000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0020
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
- Supplemental instructions
- ESD AND PHYSICAL PROTECTIO
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 2
- Orig stdzn dec
- TX
- Dt stdzn dec
- 26-FEB-1994
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.