Catalog item

WAVEGUIDE ASSEMBLY

5985FSC
00NCB code
005-2967Item number
NIIN 00-005-2967
Request a quote
Unit price
$1,208.12
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00305
PINC
0000305
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
14-JUN-72
Precious metals indicator
S
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8529109000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DSJSMSEA0.0000$1,208.12170N-------$0.00I
01-OCT-2026DFJSMSEA0.0000$1,208.12170NSF9EH-N$0.00F

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
483225-13B150
RAYTHEON COMPANY DBA RAYTHEON CO
A32ATX
483225-149956
RAYTHEON COMPANY DIV CORP
A59ATX3B
483225-154X10
RAYTHEON COMPANY
A525ZZ
483225-154647
MICROTECH INC DBA MICROTECH INC
A525ZZ
AS6C112-680006
LITTON SYSTEMS INC AIRTRON DIV
H596TX3B

Characteristics

SURFACE TREATMENTSINGLE TUBING SEGMENT OUTSIDE SURFACES CHROMATE
INSERTION LOSS IN DECIBELS0.03
WAVEGUIDE OUTSIDE WIDTHINCHES MINIMUM 1.246 AND INCHES MAXIMUM 1.254
OPERATING PRESSUREPOUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM 40.0
WAVEGUIDE INSIDE WIDTHINCHES MINIMUM 1.118 AND INCHES MAXIMUM 1.126
WAVEGUIDE INSIDE HEIGHTINCHES MINIMUM 0.493 AND INCHES MAXIMUM 0.501
WAVEGUIDE OUTSIDE HEIGHTINCHES MINIMUM 0.621 AND INCHES MAXIMUM 0.629
STYLE DESIGNATOR
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
TUBING WALL CONSTRUCTION STYLE
FLANGE QUANTITY2
FLANGE INSIDE WIDTHALL FLANGES INCHES MINIMUM 1.253 AND INCHES MAXIMUM 1.256
FLANGE INSIDE HEIGHTALL FLANGES INCHES MINIMUM 0.628 AND INCHES MAXIMUM 0.631
FLANGE OUTSIDE WIDTHALL FLANGES INCHES MINIMUM 1.860 AND INCHES MAXIMUM 1.890
FLANGE OUTSIDE HEIGHTALL FLANGES INCHES MINIMUM 1.860 AND INCHES MAXIMUM 1.890
FLANGE DEPTHALL FLANGES INCHES MINIMUM 0.423 AND INCHES MAXIMUM 0.453
SURFACE TREATMENTSINGLE TUBING SEGMENT INSIDE SURFACES SILVER
CROSS-SECTIONAL SHAPE STYLE
PRECIOUS MATERIALSILVER
SURFACE TREATMENTALL FLANGE INSIDE SURFACES SILVER
SURFACE TREATMENTALL FLANGE OUTSIDE SURFACES CHROMATE
MATERIALALL FLANGE ALUMINUM
MATERIALSINGLE TUBING JACKET RUBBER
MATERIALSINGLE TUBING SEGMENT BERYLLIUM
PRECIOUS MATERIAL AND LOCATIONSILVER FLANGE SURFACE AND TUBING INTERIOR
VOLTAGE STANDING WAVE RATIO1.10
FLANGE CONNECTING FACILITY AND QUANTITYALL FLANGES ALL CONNECTION FACILITIES UNTHREADED HOLE(S) 4
FLANGE STYLE
FLANGE CONNECTING HOLE DIAMETERSINGLE FLANGE ALL CONNECTION FACILITIES INCHES MINIMUM 0.169 AND INCHES MAXIMUM 0.172
FLEXIBILITYSINGLE TUBING SEGMENT FLEXIBLE
WAVEGUIDE LENGTHINCHES NOMINAL 6.000

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
ZG01ZG01-APR-91ZG81ZG
FXGXDF1C01-NOV-05ZSXGX01SX5DGX TUFXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
723
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
42
Container, watervaporproof bag, heat sealed, container
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.3000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0310
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
25-NOV-1983
NIIN status code
0

Request a quote