Catalog item

WAVEGUIDE ASSEMBLY

5985FSC
00NCB code
072-9607Item number
NIIN 00-072-9607
Request a quote
Unit price
$3,602.16
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00305
PINC
0000305
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8529109000
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNXSMSEA0.0000$3,602.161709B-----$0.00N
01-OCT-2026DSXSMSEA0.0000$3,602.16170-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
2269824REVC53711
NAVAL SEA SYSTEMS COMMAND
AC16ZZAC
100564856232
LOCKHEED MARTIN CORPORATION DIV RMS - MITCHEL FIELD
A521XX3D
226982410001
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
A32ATX3D

Characteristics

FLEXIBILITYSINGLE TUBING SEGMENT RIGID
MATERIALALL FLANGE ALUMINUM ALLOY
FLANGE STYLE
SPECIAL FEATURESTUBING WALL CONSTRUCTION CAN BE LAMINATED; FLANGE FACES FREE OF SURFACE TREATMENTS; MTG BRACKET ON TUBING SEGMENT
FLANGE CONNECTING FACILITY AND QUANTITYFIRST FLANGE SINGLE CONNECTION FACILITY THREADED HOLE(S) 8
FLANGE CONNECTING FACILITY AND QUANTITYSECOND FLANGE SINGLE CONNECTION FACILITY UNTHREADED HOLE(S) 8
STYLE DESIGNATOR
THREAD SERIES DESIGNATORFIRST FLANGE SINGLE CONNECTION FACILITY UNIFIED NATIONAL COARSE (UNC)
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
BEND ANGLE IN DEG43.1
BEND ANGLE IN DEG90.0
END ITEM IDENTIFICATIONRADAR SET AN/SPG-55B
TUBING WALL CONSTRUCTION STYLE
FLANGE QUANTITY2
FLANGE INSIDE WIDTHFIRST FLANGE INCHES MINIMUM 1.868 AND INCHES MAXIMUM 1.876
FLANGE INSIDE WIDTHSECOND FLANGE INCHES MINIMUM 2.002 AND INCHES MAXIMUM 2.005
FLANGE INSIDE HEIGHTFIRST FLANGE INCHES MINIMUM 0.868 AND INCHES MAXIMUM 0.876
FLANGE INSIDE HEIGHTSECOND FLANGE INCHES MINIMUM 1.002 AND INCHES MAXIMUM 1.005
FLANGE OUTSIDE DIAMETERFIRST FLANGE INCHES NOMINAL 3.625
FLANGE OUTSIDE DIAMETERSECOND FLANGE INCHES NOMINAL 3.625
FLANGE DEPTHFIRST FLANGE INCHES NOMINAL 0.938
FLANGE DEPTHSECOND FLANGE INCHES NOMINAL 0.281
FLANGE CONNECTING HOLE DIAMETERSECOND FLANGE SINGLE CONNECTION FACILITY INCHES MINIMUM 0.203 AND INCHES MAXIMUM 0.209
WAVEGUIDE OUTSIDE WIDTHINCHES MINIMUM 1.995 AND INCHES MAXIMUM 2.005
NOMINAL THREAD SIZEFIRST FLANGE SINGLE CONNECTION FACILITY INCHES 0.190
WAVEGUIDE INSIDE WIDTHINCHES MINIMUM 1.867 AND INCHES MAXIMUM 1.877
WAVEGUIDE INSIDE HEIGHTINCHES MINIMUM 0.867 AND INCHES MAXIMUM 0.877
WAVEGUIDE OUTSIDE HEIGHTINCHES MINIMUM 0.995 AND INCHES MAXIMUM 1.005
MATERIALSINGLE TUBING SEGMENT ALUMINUM ALLOY
SURFACE TREATMENTALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES CHROMATE AND CHROMATE ZINC AND ENAMEL
CROSS-SECTIONAL SHAPE STYLE
THREAD CLASS2B
THREAD DIRECTIONFIRST FLANGE SINGLE CONNECTION FACILITY RIGHT-HAND

MOE rules

MOE rule
N9BN
MOE CD
DN
AMC
3
AMSC
C
Date assigned
01-JUL-05
IMC
Z
IMCA
HD
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX
Supp collab
HD
Fmr MOE rl
N9ND

Service data

Navy

COG
9B

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
723
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
E5
ASTM D5118/D5118M, fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
6
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
BF
Dt stdzn dec
17-APR-1973
NIIN status code
0

Request a quote