Catalog item

WAVEGUIDE ASSEMBLY

5985FSC
00NCB code
102-4202Item number
NIIN 00-102-4202
Request a quote
Unit price
$381.33
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00305
PINC
0000305
Criticality code
X
II
M
DEMIL code
D
NIIN assigned
29-MAY-68
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8529109000

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
J
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$381.33
Quantity per unit pack
1
Controlled inventory item code
7
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
C1-4654152564
MEGA INDUSTRIES INC MEGA MICROWAVE DIV
A526HD
C1-4654181482
PAGE CHESTER LTD DBA COOPERATIVE INDUSTRIES DIV COOPERATIVE INDUSTRIES AEROSPACE DEFENSE
A596HD1B
2546031-110001
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
A321HD1A

Characteristics

FLANGE DEPTHSECOND FLANGE INCHES MINIMUM 0.423 AND INCHES MAXIMUM 0.453
STYLE DESIGNATOR
THREAD SERIES DESIGNATORFIRST FLANGE SINGLE CONNECTION FACILITY UNIFIED NATIONAL COARSE (UNC)
FLANGE OUTSIDE HEIGHTFIRST FLANGE INCHES MINIMUM 1.610 AND INCHES MAXIMUM 1.640
SURFACE TREATMENTSINGLE TUBING SEGMENT INSIDE SURFACES NICKEL
MATERIALSINGLE TUBING SEGMENT STEEL CORROSION RESISTING
FLANGE DEPTHFIRST FLANGE INCHES MINIMUM 0.423 AND INCHES MAXIMUM 0.453
FLANGE STYLE
WAVEGUIDE OFFSET DISTANCEINCHES MINIMUM 0.610 AND INCHES MAXIMUM 0.670
FLEXIBILITYSINGLE TUBING SEGMENT RIGID
MATERIALSINGLE TUBING JACKET RUBBER SYNTHETIC
FLANGE CONNECTING FACILITY AND QUANTITYSECOND FLANGE SINGLE CONNECTION FACILITY THREADED HOLE(S) 4
FLANGE CONNECTING HOLE DIAMETERSECOND FLANGE SINGLE CONNECTION FACILITY INCHES MINIMUM 0.169 AND INCHES MAXIMUM 0.172
VOLTAGE STANDING WAVE RATIO1.06
WAVEGUIDE OUTSIDE WIDTHINCHES MINIMUM 0.997 AND INCHES MAXIMUM 1.003
FLANGE INSIDE HEIGHTFIRST FLANGE INCHES MINIMUM 0.397 AND INCHES MAXIMUM 0.403
CROSS-SECTIONAL SHAPE STYLE
THREAD CLASS2B
THREAD DIRECTIONFIRST FLANGE SINGLE CONNECTION FACILITY RIGHT-HAND
TUBING WALL CONSTRUCTION STYLE
FLANGE OUTSIDE HEIGHTSECOND FLANGE INCHES MINIMUM 1.610 AND INCHES MAXIMUM 1.640
WAVEGUIDE INSIDE HEIGHTINCHES MINIMUM 0.397 AND INCHES MAXIMUM 0.403
WAVEGUIDE OUTSIDE HEIGHTINCHES MINIMUM 0.497 AND INCHES MAXIMUM 0.503
WAVEGUIDE LONGER OFFSET DISTANCEINCHES MINIMUM 2.870 AND INCHES MAXIMUM 2.930
FLANGE CONNECTING FACILITY AND QUANTITYFIRST FLANGE SINGLE CONNECTION FACILITY UNTHREADED HOLE(S) 4
FLANGE INSIDE HEIGHTSECOND FLANGE INCHES MINIMUM 0.397 AND INCHES MAXIMUM 0.403
FLANGE OUTSIDE WIDTHFIRST FLANGE INCHES MINIMUM 1.610 AND INCHES MAXIMUM 1.640
FLANGE OUTSIDE WIDTHSECOND FLANGE INCHES MINIMUM 1.610 AND INCHES MAXIMUM 1.640
FLANGE INSIDE WIDTHSECOND FLANGE INCHES MINIMUM 0.897 AND INCHES MAXIMUM 0.903
NOMINAL THREAD SIZEFIRST FLANGE SINGLE CONNECTION FACILITY INCHES 0.138
OPERATING PRESSUREPOUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM 5.0
WAVEGUIDE INSIDE WIDTHINCHES MINIMUM 0.897 AND INCHES MAXIMUM 0.903
FLANGE INSIDE DIAMETERFIRST FLANGE INCHES MINIMUM 1.000 AND INCHES MAXIMUM 1.006
FLANGE INSIDE DIAMETERSECOND FLANGE INCHES MINIMUM 1.000 AND INCHES MAXIMUM 1.006
FLANGE INSIDE WIDTHFIRST FLANGE INCHES MINIMUM 0.897 AND INCHES MAXIMUM 0.903
FLANGE QUANTITY2

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedPICAPICA LOAAuth collab
YB01YB01-FEB-94YB81YB
ZJ01ZJ01-APR-25ZJ81ZJ
DGX1DS2G01-NOV-25GX01GX

Freight

ACTY CD
HH
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
723
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69FZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
BF
Dt stdzn dec
17-APR-1973
NIIN status code
0

Request a quote