Catalog item

SWITCH,WAVEGUIDE

5985FSC
00NCB code
177-7121Item number
NIIN 00-177-7121
Request a quote
Unit price
$12,172.74
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
05118
PINC
0005118
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
08-DEC-71
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8529109000
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFZSMSEA0.0000$12,172.741U0NSF9EH-N$0.00F
01-OCT-2026DNZSMSEA0.0000$12,172.741U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$12,172.741U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
WS-01X11-16A24022
TELEDYNE DEFENSE ELECTRONICS, LLC DBA TELEDYNE MICROWAVE SOLUTIONS
A52BTX4A
WS01X11-1624022
TELEDYNE DEFENSE ELECTRONICS, LLC DBA TELEDYNE MICROWAVE SOLUTIONS
A595TX1B
25338182577
RAYTHEON COMPANY DBA RAYTHEON
A32ATX4D
L0X30309080
LOGUS MANUFACTURING CORP.
A525TX4D

Characteristics

FREQUENCY RATINGSINGLE FREQUENCY CROSSTALK REFERENCE GIGAHERTZ MINIMUM 8.2 AND GIGAHERTZ MAXIMUM 12.4
FREQUENCY RATINGSINGLE FREQUENCY INSERTION LOSS REFERENCE GIGAHERTZ MINIMUM 8.2 AND GIGAHERTZ MAXIMUM 12.4
BODY STYLE
OVERALL LENGTHINCHES MAXIMUM 3.600
OVERALL HEIGHTINCHES NOMINAL 1.875
OVERALL WIDTHINCHES NOMINAL 2.288
THREAD CLASS2B
SWITCHING TIMEMILLISECONDS 150.0
SWITCH RETURN MECHANISM TYPEFAIL-SAFE
WAVEGUIDE FLANGE TYPECHOKE
COUPLING POSITION QUANTITY1
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 4
NOMINAL THREAD SIZEFLANGE CONNECTION FACILITY HOLE INCHES 0.164
FREQUENCY RATINGSINGLE FREQUENCY VOLTAGE STANDING WAVE RATIO GIGAHERTZ MINIMUM 8.2 AND GIGAHERTZ MAXIMUM 12.4
SWITCH TYPETRANSFER
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERSSINGLE MOUNTING FACILITY PATTERN INCHES NOMINAL 0.813
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERSSINGLE MOUNTING FACILITY PATTERN INCHES NOMINAL 1.281
OPERATING TEMP RANGECELSIUS -54.0 TO 85.0
VOLTAGE STANDING WAVE RATIO1.10
INSERTION LOSS IN DECIBELS0.20
MINIMUM CROSSTALK RATING IN DECIBELS50.0
ACTUATOR OPERATING METHODRELAY
ACTUATOR CURRENT TYPE AND RATING IN AMPSDC MAXIMUM 0.9
ACTUATOR VOLTAGE IN VOLTSMINIMUM 24.0 AND MAXIMUM 30.0
THREAD SERIES DESIGNATORFLANGE CONNECTION FACILITY HOLE UNIFIED NATIONAL COARSE (UNC)
THREAD SERIES DESIGNATORMOUNTING FACILITY HOLE UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTURRET 4 AND RECTANGULAR FLANGE 1
PROPRIETARY CHARACTERISTICSPACS
SURFACE TREATMENTBODY OUTSIDE SURFACES ENAMEL
MATERIALBODY ALUMINUM ALLOY
MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY PATTERN FOUR POSITION RECTANGULAR
FLANGE CONNECTING FACILITY AND QUANTITYTHREADED HOLE(S) 16
NOMINAL THREAD SIZEMOUNTING FACILITY HOLE INCHES 0.164

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
FXGXDF1G01-APR-06ZSXGX01SX5DGX TUFXTX
N9BNDN1G01-APR-06ZKEGX01GH5DGXGT KEN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
KE
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
EA
MIL-DTL-17667, neutral wrapping paper
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.4000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0520
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
03-MAR-1978
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.