Catalog item

SWITCH,WAVEGUIDE

5985FSC
00NCB code
189-3299Item number
NIIN 00-189-3299
Request a quote
Unit price
$5,667.18
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
05118
PINC
0005118
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
05-MAR-71
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8529109000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$5,667.181U0PSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$5,667.181U0F-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
33 D 2130050140
K&L MICROWAVE LLC DIV MPG HOLDING COMPANY
A525TX
33 D 2130082152
FISICA APPLIED TECHNOLOGIES, INC. DIV DATRON ADVANCED TECHNOLOGIES
A595TXB
533818-296214
RAYTHEON COMPANY DBA RAYTHEON
A321TX3D
20-2344P201456
MICROWAVE DEVELOPMENT LABORATORIES, INC. DBA MICROWAVE DEVELOPMENT LABORATORIES INC
A526TX3D

Characteristics

FREQUENCY RATINGSINGLE FREQUENCY INSERTION LOSS REFERENCE GIGAHERTZ MINIMUM 9.0 AND GIGAHERTZ MAXIMUM 9.6
NOMINAL THREAD SIZEFLANGE CONNECTION FACILITY HOLE INCHES 0.164
INSERTION LOSS IN DECIBELS0.10
FREQUENCY RATINGSINGLE FREQUENCY VOLTAGE STANDING WAVE RATIO GIGAHERTZ MINIMUM 9.0 AND GIGAHERTZ MAXIMUM 9.6
MINIMUM CROSSTALK RATING IN DECIBELS50.0
ACTUATOR OPERATING METHODRELAY
ACTUATOR VOLTAGE IN VOLTSNOMINAL 28.0
SWITCHING TIMEMILLISECONDS 100.0
WAVEGUIDE FLANGE TYPECHOKE
COUPLING POSITION QUANTITY4
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 4
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERSSINGLE MOUNTING FACILITY PATTERN INCHES NOMINAL 0.812
NOMINAL THREAD SIZEMOUNTING FACILITY HOLE INCHES 0.164
MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY PATTERN FOUR POSITION RECTANGULAR
FLANGE CONNECTING FACILITY AND QUANTITYTHREADED HOLE(S) 4
MATERIALBODY METAL
SURFACE TREATMENTBODY OUTSIDE SURFACES ENAMEL
THREAD SERIES DESIGNATORFLANGE CONNECTION FACILITY HOLE UNIFIED NATIONAL COARSE (UNC)
THREAD SERIES DESIGNATORMOUNTING FACILITY HOLE UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYRECEPTACLE, COAXIAL 1 AND RECTANGULAR FLANGE 4
SWITCH TYPETRANSFER
BODY STYLE
OVERALL WIDTHINCHES NOMINAL 2.938
FREQUENCY RATINGSINGLE FREQUENCY OPERATING GIGAHERTZ MINIMUM 9.0 AND GIGAHERTZ MAXIMUM 9.6
FREQUENCY RATINGSINGLE FREQUENCY RF POWER HANDLING GIGAHERTZ MINIMUM 9.0 AND GIGAHERTZ MAXIMUM 9.6
RF POWER HANDLING CAPABILITYSINGLE KILOWATTS PEAK 125.0
OVERALL LENGTHINCHES NOMINAL 4.000
OVERALL HEIGHTINCHES NOMINAL 1.870
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERSSINGLE MOUNTING FACILITY PATTERN INCHES NOMINAL 1.281
OPERATING TEMP RANGECELSIUS -55.0 TO 100.0
VOLTAGE STANDING WAVE RATIO1.08

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
WP01WP01-JUN-11WP81WP
YB01YB01-APR-91YB81YB
YD01YD01-JUN-24YD81YD
ZP01ZP01-APR-91ZP81ZP
ZU01ZU01-MAR-08ZU81ZU
FXGXDF1G01-APR-06ZSXGX01SX5DGX TUFXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
P

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
62Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
52
Container, watervaporproof bag, heat sealed, container, with desiccant
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
03
Method 50
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
1.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0460
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
ATTENTION: USE SPECIAL M

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
21-MAR-1971
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.