Catalog item

WAVEGUIDE ASSEMBLY

5985FSC
00NCB code
396-3669Item number
NIIN 00-396-3669
Request a quote
Unit price
$785.06
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00305
PINC
0000305
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
12-APR-74
Precious metals indicator
S
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8529109000

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
Y
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$785.06
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
21357754647
MICROTECH INC DBA MICROTECH INC
A525TX
TRS5714706351
MICROWAVE ENGINEERING CORPORATION
A525TXD
V00660-04112436
BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC. DIV BAE SYSTEMS INFORMATION & ELECTRONIC SYSTEMS INTEGRATION INC
A32ATX

Characteristics

SURFACE TREATMENTFIFTH TUBING SEGMENT INSIDE SURFACES SILVER
VOLTAGE STANDING WAVE RATIO1.30
SURFACE TREATMENTSIXTH TUBING SEGMENT OUTSIDE SURFACES COPPER ALLOY AND PAINT
SURFACE TREATMENTTHIRD TUBING SEGMENT OUTSIDE SURFACES COPPER ALLOY AND PAINT
INSERTION LOSS IN DECIBELS0.35
MATERIALFOURTH TUBING SEGMENT COPPER ALLOY
MATERIALSECOND TUBING SEGMENT COPPER ALLOY
WAVEGUIDE OUTSIDE HEIGHTINCHES MINIMUM 0.388 AND INCHES MAXIMUM 0.394
MATERIALSIXTH TUBING SEGMENT COPPER ALLOY
MATERIALTHIRD TUBING SEGMENT COPPER ALLOY
FLANGE CONNECTING FACILITY AND QUANTITYALL FLANGES ALL CONNECTION FACILITIES UNTHREADED HOLE(S) 4
CROSS-SECTIONAL SHAPE STYLE
TUBING WALL CONSTRUCTION STYLE
TUBING TWIST TYPEFIFTH TUBING SEGMENT TWISTABLE
FLANGE QUANTITY2
FLANGE INSIDE WIDTHALL FLANGES INCHES MINIMUM 0.705 AND INCHES MAXIMUM 0.707
FLANGE INSIDE HEIGHTALL FLANGES INCHES MINIMUM 0.394 AND INCHES MAXIMUM 0.396
FLANGE OUTSIDE WIDTHALL FLANGES INCHES MINIMUM 1.298 AND INCHES MAXIMUM 1.328
FLANGE OUTSIDE HEIGHTALL FLANGES INCHES MINIMUM 1.298 AND INCHES MAXIMUM 1.328
FLANGE DEPTHALL FLANGES INCHES MINIMUM 0.298 AND INCHES MAXIMUM 0.328
FLANGE CONNECTING HOLE DIAMETERALL FLANGES ALL CONNECTION FACILITIES INCHES MINIMUM 0.144 AND INCHES MAXIMUM 0.147
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
SURFACE TREATMENTSECOND TUBING SEGMENT OUTSIDE SURFACES COPPER ALLOY AND PAINT
WAVEGUIDE OUTSIDE WIDTHINCHES MINIMUM 0.699 AND INCHES MAXIMUM 0.705
WAVEGUIDE INSIDE WIDTHINCHES MINIMUM 0.6195 AND INCHES MAXIMUM 0.6245
WAVEGUIDE INSIDE HEIGHTINCHES MINIMUM 0.3085 AND INCHES MAXIMUM 0.3135
SURFACE TREATMENTFIRST TUBING SEGMENT OUTSIDE SURFACES COPPER AND PAINT
SURFACE TREATMENTFOURTH TUBING SEGMENT OUTSIDE SURFACES COPPER ALLOY AND PAINT
FLANGE STYLE
SPECIAL FEATURESFIVE REMAINING SECTIONS OF WAVEGUIDE AND FLANGES ARE COPPER; COPPER CHROMATE TREATED AND PAINTED; FREQUENCY RANGE 15.9 TO 17.1 GHZ
FLEXIBILITYFIFTH TUBING SEGMENT FLEXIBLE
FLEXIBILITYFIRST TUBING SEGMENT RIGID
FLEXIBILITYFOURTH TUBING SEGMENT RIGID
FLEXIBILITYSECOND TUBING SEGMENT RIGID
FLEXIBILITYSIXTH TUBING SEGMENT RIGID
FLEXIBILITYTHIRD TUBING SEGMENT RIGID
MATERIALFIFTH TUBING SEGMENT COPPER ALLOY
MATERIALFIRST TUBING SEGMENT COPPER ALLOY
PRECIOUS MATERIAL AND LOCATIONSILVER INTERNAL SURFACES FLEXIBLE WAVEGUIDE SECTION
PRECIOUS MATERIALSILVER

MOE rules

MOE rule
DGX1
MOE CD
DS
AMC
1
AMSC
C
Date assigned
01-APR-06
PICA
GX
PICA LOA
01
Auth collab
GX
Supp collab
TX
Fmr MOE rl
DTX1

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
723
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
2.2000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.5160
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
97035

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
18-APR-1974
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.