Catalog item

ADAPTER,WAVEGUIDE

5985FSC
00NCB code
402-0053Item number
NIIN 00-402-0053
Request a quote
Unit price
$1,009.62
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00186
PINC
0000186
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
08-APR-70
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8529109000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$1,009.62170NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$1,009.621709B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,009.62170N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
612A99899
NARDA HOLDINGS, INC. DBA NARDA-MITEQ
A59ETX3B
M20-3821-2155-22F4060
ARIANEGROUP SAS
A525TX4D
N101A-115400341
LEXAN INDUSTRIES, INC DBA STRUTHERS ELECTRONICS DIV STRUTHERS ELECTRONICS
H395TX
1793C234-116111
RODALE ELECTRONICS INC. DBA RODALE WIRELESS
H79ATX3D

Characteristics

FLANGE CONNECTING HOLE DIAMETERSINGLE FLANGE ALL CONNECTION FACILITIES INCHES MINIMUM 0.199 AND INCHES MAXIMUM 0.203
FLANGE STYLE
FLANGE DEPTHSINGLE FLANGE INCHES MINIMUM 0.360 AND INCHES MAXIMUM 0.390
WAVEGUIDE OUTSIDE WIDTHINCHES MINIMUM 1.496 AND INCHES MAXIMUM 1.504
WAVEGUIDE INSIDE HEIGHTINCHES MINIMUM 0.618 AND INCHES MAXIMUM 0.626
COAXIAL CONNECTOR SERIES DESIGNATIONN
ADAPTER OVERALL HEIGHTINCHES MINIMUM 3.062 AND INCHES MAXIMUM 3.092
END ITEM IDENTIFICATIONTEST SET,TRANSPONDER SET AN/DPM-19(XN-1); TEST SET,TRANSPONDER SET AN/DPM-20(XN-1)
TUBING WALL CONSTRUCTION STYLE
FLANGE QUANTITY1
SPECIAL FEATURESFREQUENCY RANGE 5.30 TO 8.20 GHZ
MATERIALSINGLE TUBING SEGMENT AND FLANGE ALUMINUM ALLOY
STYLE DESIGNATOR
SPECIFICATION/STANDARD DATAMANUFACTURERS SPECIFICATION CONTROL 16111-1793C234
FSC APPLICATION DATARADAR EQUIPMENT
CONNECTOR END DESIGNFEMALE
WAVEGUIDE INSIDE WIDTHINCHES MINIMUM 1.368 AND INCHES MAXIMUM 1.376
CROSS-SECTIONAL SHAPE STYLE
WAVEGUIDE OUTSIDE HEIGHTINCHES MINIMUM 0.746 AND INCHES MAXIMUM 0.754
FLANGE CONNECTING FACILITY AND QUANTITYSINGLE FLANGE SINGLE CONNECTION FACILITY UNTHREADED HOLE(S) 6
ADAPTER DIAMETERINCHES MINIMUM 3.110 AND INCHES MAXIMUM 3.140
FLANGE OUTSIDE DIAMETERSINGLE FLANGE INCHES MINIMUM 3.120 AND INCHES MAXIMUM 3.130
VOLTAGE STANDING WAVE RATIO1.35
FLANGE INSIDE WIDTHSINGLE FLANGE INCHES MINIMUM 1.503 AND INCHES MAXIMUM 1.506
FLANGE INSIDE HEIGHTSINGLE FLANGE INCHES MINIMUM 0.753 AND INCHES MAXIMUM 0.756
ADAPTER LENGTHINCHES MINIMUM 1.735 AND INCHES MAXIMUM 1.765

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZN01ZN01-JAN-99ZN81ZN
ZW01ZW01-NOV-05ZW81ZW
FXGXDF1Z01-APR-06ZSXGX01SX5DGX TUFXTX
N9BNDN1Z01-APR-06ZKEGX01GH5DGXKEN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
KE
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.5000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0370
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
28-APR-1970
NIIN status code
0

Request a quote