Catalog item

WAVEGUIDE ASSEMBLY

5985FSC
00NCB code
417-6246Item number
NIIN 00-417-6246
Request a quote
Unit price
$626.03
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00305
PINC
0000305
Criticality code
X
II
0
DEMIL code
D
NIIN assigned
02-FEB-72
Precious metals indicator
S
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8529109000
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$626.03170AQ2200X-$0.00A
01-OCT-2026DSJSMSEA0.0000$626.03170-------$0.00I

Part numbers

Part number
SMC652134
CAGE
80063
US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
CAGE status
A
RNCC
3
RNVC
2
Document availability code
A
RNAAC
TX
RNFC
3
RNSC
D

Characteristics

SURFACE TREATMENTALL FLANGE OUTSIDE SURFACES PAINT
MATERIALSINGLE TUBING JACKET RUBBER
SURFACE TREATMENTFIRST FLANGE OUTSIDE SURFACES SILVER
FLANGE DEPTHFIRST FLANGE INCHES MINIMUM 0.922 AND INCHES MAXIMUM 0.953
FLANGE DEPTHSECOND FLANGE INCHES MINIMUM 0.360 AND INCHES MAXIMUM 0.390
THREAD DIRECTIONFIRST FLANGE ALL CONNECTION FACILITIES RIGHT-HAND
TUBING WALL CONSTRUCTION STYLE
FLANGE QUANTITY2
FLANGE INSIDE WIDTHFIRST FLANGE INCHES MINIMUM 1.867 AND INCHES MAXIMUM 1.877
FLANGE INSIDE WIDTHSECOND FLANGE INCHES MINIMUM 2.002 AND INCHES MAXIMUM 2.005
FLANGE INSIDE HEIGHTFIRST FLANGE INCHES MINIMUM 0.867 AND INCHES MAXIMUM 0.877
CROSS-SECTIONAL SHAPE STYLE
MATERIALSINGLE TUBING SEGMENT COPPER ALLOY
SURFACE TREATMENTSECOND FLANGE OUTSIDE SURFACES CHROMATE
FLANGE INSIDE HEIGHTSECOND FLANGE INCHES MINIMUM 1.002 AND INCHES MAXIMUM 1.005
FLANGE OUTSIDE DIAMETERFIRST FLANGE INCHES MINIMUM 3.610 AND INCHES MAXIMUM 3.640
MATERIALFIRST FLANGE COPPER ALLOY
MATERIALSECOND FLANGE ALUMINUM ALLOY
FLANGE CONNECTING FACILITY AND QUANTITYFIRST FLANGE ALL CONNECTION FACILITIES THREADED HOLE(S) 8
FLANGE CONNECTING FACILITY AND QUANTITYSECOND FLANGE ALL CONNECTION FACILITIES UNTHREADED HOLE(S) 8
FLANGE STYLE
FLANGE OUTSIDE DIAMETERSECOND FLANGE INCHES MINIMUM 3.610 AND INCHES MAXIMUM 3.640
VOLTAGE STANDING WAVE RATIO1.08
INSERTION LOSS IN DECIBELS0.10
WAVEGUIDE OUTSIDE WIDTHINCHES MINIMUM 1.995 AND INCHES MAXIMUM 2.005
NOMINAL THREAD SIZEFIRST FLANGE ALL CONNECTION FACILITIES INCHES 0.190
WAVEGUIDE INSIDE WIDTHINCHES MINIMUM 0.995 AND INCHES MAXIMUM 1.005
WAVEGUIDE INSIDE HEIGHTINCHES MINIMUM 0.867 AND INCHES MAXIMUM 0.877
WAVEGUIDE OUTSIDE HEIGHTINCHES MINIMUM 1.867 AND INCHES MAXIMUM 1.877
SURFACE TREATMENTSINGLE TUBING SEGMENT INSIDE SURFACES SILVER
STYLE DESIGNATOR
THREAD SERIES DESIGNATORFIRST FLANGE ALL CONNECTION FACILITIES UNIFIED NATIONAL COARSE (UNC)
WAVEGUIDE CENTER TO CENTER DISTANCEINCHES MINIMUM 6.670 AND INCHES MAXIMUM 6.730
WAVEGUIDE HEIGHTINCHES MINIMUM 3.940 AND INCHES MAXIMUM 4.060
FLEXIBILITYSINGLE TUBING SEGMENT FLEXIBLE
FLANGE CONNECTING HOLE DIAMETERSECOND FLANGE ALL CONNECTION FACILITIES INCHES MINIMUM 0.199 AND INCHES MAXIMUM 0.203
FSC APPLICATION DATAANTENNAS, WAVEGUIDES, AND RELATED EQUIPMENT
THREAD CLASS2B
PRECIOUS MATERIAL AND LOCATIONSILVER INTERNAL SURFACES
PRECIOUS MATERIALSILVER

MOE rules

MOE rule
A918
MOE CD
DA
AMC
1
AMSC
G
Date assigned
01-APR-06
IMC
Z
IMCA
CL
PICA
GX
PICA LOA
01
SICA
CD
SICA LOA
5D
Auth collab
CD GX
Supp collab
CL
Fmr MOE rl
A196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
CL
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
723
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69FZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
10.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.4950
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
92338

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
10-FEB-1972
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.