Catalog item

WAVEGUIDE ASSEMBLY

5985FSC
00NCB code
549-5761Item number
NIIN 00-549-5761
Request a quote
Unit price
$959.86
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00305
PINC
0000305
Criticality code
X
II
M
DEMIL code
D
NIIN assigned
18-OCT-74
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8529109000
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$959.861709B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$959.86170-------$0.00I

Part numbers

Part number
2835928
CAGE
10001
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
CAGE status
A
RNCC
3
RNVC
2
Document availability code
1
RNAAC
HD
RNFC
3
RNSC
D

Characteristics

FLANGE OUTSIDE HEIGHTSECOND FLANGE INCHES MAXIMUM 1.890
WAVEGUIDE INSIDE WIDTHINCHES MINIMUM 1.118 AND INCHES MAXIMUM 1.126
FLANGE OUTSIDE HEIGHTFIRST FLANGE INCHES MINIMUM 1.860
FLANGE INSIDE HEIGHTALL FLANGES INCHES MINIMUM 0.628 AND INCHES MAXIMUM 0.631
FLANGE OUTSIDE WIDTHALL FLANGES INCHES MINIMUM 1.860 AND INCHES MAXIMUM 1.890
FLANGE CONNECTING FACILITY AND QUANTITYALL FLANGES SINGLE CONNECTION FACILITY UNTHREADED HOLE(S) 4
WAVEGUIDE INSIDE HEIGHTINCHES MINIMUM 0.493 AND INCHES MAXIMUM 0.501
WAVEGUIDE OUTSIDE HEIGHTINCHES MINIMUM 0.621 AND INCHES MAXIMUM 0.629
SPECIAL FEATURESTUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED
FLANGE DEPTHALL FLANGES INCHES MINIMUM 0.922 AND INCHES MAXIMUM 0.953
FLANGE CONNECTING HOLE DIAMETERALL FLANGES SINGLE CONNECTION FACILITY INCHES MINIMUM 0.169 AND INCHES MAXIMUM 0.172
VOLTAGE STANDING WAVE RATIO1.05
INSERTION LOSS IN DECIBELS0.05
STYLE DESIGNATOR
FLANGE QUANTITY2
WAVEGUIDE LONGER OFFSET DISTANCEINCHES NOMINAL 1.625
CROSS-SECTIONAL SHAPE STYLE
BEND ANGLE IN DEG90.0
TUBING WALL CONSTRUCTION STYLE
FLANGE INSIDE WIDTHALL FLANGES INCHES MINIMUM 1.253 AND INCHES MAXIMUM 1.256
FLEXIBILITYSINGLE TUBING SEGMENT RIGID
MATERIALALL FLANGE ALUMINUM ALLOY
MATERIALSINGLE TUBING SEGMENT ALUMINUM ALLOY
SURFACE TREATMENTALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES OXIDE FILM
WAVEGUIDE OUTSIDE WIDTHINCHES MINIMUM 1.246 AND INCHES MAXIMUM 1.254
FLANGE STYLE
WAVEGUIDE OFFSET DISTANCEINCHES NOMINAL 1.500
OPERATING PRESSUREPOUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM 10.0

MOE rules

MOE rule
N9BN
MOE CD
DN
AMC
2
AMSC
G
Date assigned
01-APR-06
IMC
Z
IMCA
HD
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX
Supp collab
HD
Fmr MOE rl
N9ND

Service data

Navy

COG
9B

Freight

ACTY CD
HD
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
723
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69FZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.8000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0970
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
03-OCT-1992
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.