Catalog item

WAVEGUIDE ASSEMBLY

5985FSC
00NCB code
802-7540Item number
NIIN 00-802-7540
Request a quote
Unit price
$225.15
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00305
PINC
0000305
Criticality code
X
II
0
DEMIL code
D
NIIN assigned
01-JAN-62
Precious metals indicator
P
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8529109000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAXSMSEA0.0000$225.15170ZQ2200X-$0.00A
01-OCT-2026DSXSMSEA0.0000$225.15170N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
TS64514220019
WARD LEONARD CT LLC
A525TX
91764313B150
RAYTHEON COMPANY DBA RAYTHEON CO
A525TX
917643149956
RAYTHEON COMPANY DIV CORP
A595TXB
917643154X10
RAYTHEON COMPANY
A525ZZ
917643118876
US ARMY AVIATION AND MISSILE COMMAND
A32ATX3D

Characteristics

FLEXIBILITYSINGLE TUBING SEGMENT FLEXIBLE
PRECIOUS MATERIAL AND LOCATIONRHODIUM ALL SURFACES
PRECIOUS MATERIALRHODIUM
SURFACE TREATMENTALL TUBING SEGMENT AND FLANGE ALL SURFACES RHODIUM
STYLE DESIGNATOR
FSC APPLICATION DATARADAR EQUIP.
FLANGE STYLE
WAVEGUIDE LEG LENGTHINCHES MINIMUM 3.297 AND INCHES MAXIMUM 3.328
CROSS-SECTIONAL SHAPE STYLE
WAVEGUIDE OUTSIDE HEIGHTINCHES MINIMUM 0.496 AND INCHES MAXIMUM 0.504
WAVEGUIDE LONGER LEG LENGTHINCHES MINIMUM 4.172 AND INCHES MAXIMUM 4.203
WAVEGUIDE CENTER TO CENTER DISTANCEINCHES MINIMUM 3.766 AND INCHES MAXIMUM 3.797
WAVEGUIDE HEIGHTINCHES MINIMUM 4.172 AND INCHES MAXIMUM 4.203
WAVEGUIDE INSIDE WIDTHINCHES MINIMUM 0.896 AND INCHES MAXIMUM 0.904
WAVEGUIDE INSIDE HEIGHTINCHES MINIMUM 0.396 AND INCHES MAXIMUM 0.404
MATERIALSINGLE TUBING JACKET RUBBER SYNTHETIC
FLANGE CONNECTING FACILITY AND QUANTITYALL FLANGES SINGLE CONNECTION FACILITY UNTHREADED HOLE(S) 4
INSERTION LOSS IN DECIBELS0.15
WAVEGUIDE OUTSIDE WIDTHINCHES MINIMUM 0.996 AND INCHES MAXIMUM 1.004
OPERATING PRESSUREPOUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM 20.0
FLANGE CONNECTING HOLE DIAMETERALL FLANGES SINGLE CONNECTION FACILITY INCHES MINIMUM 0.169
VOLTAGE STANDING WAVE RATIO1.10
FLANGE OUTSIDE WIDTHALL FLANGES INCHES MINIMUM 1.610 AND INCHES MAXIMUM 1.640
FLANGE OUTSIDE HEIGHTALL FLANGES INCHES MINIMUM 1.610 AND INCHES MAXIMUM 1.640
FLANGE DEPTHALL FLANGES INCHES MINIMUM 0.423 AND INCHES MAXIMUM 0.453
FLANGE QUANTITY2
FLANGE INSIDE WIDTHALL FLANGES INCHES MINIMUM 1.003
FLANGE INSIDE HEIGHTALL FLANGES INCHES MINIMUM 0.503
TUBING WALL CONSTRUCTION STYLE
BEND ANGLE IN DEG180.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
YB01YB01-FEB-94YB81YB
ZH01ZH01-APR-91ZH81ZH
ZJ01ZJ01-APR-25ZJ81ZJ
ZU01ZU01-APR-91ZU81ZU
A918DA1G01-APR-06ZCDGX01CD5DCD GXA196
VJ01VJ01-DEC-18VJ81VJ

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
723
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
1.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0110
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
BD
Dt stdzn dec
08-NOV-1968
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.