Catalog item

WAVEGUIDE ASSEMBLY

5985FSC
01NCB code
017-8269Item number
NIIN 01-017-8269
Request a quote
Unit price
$1,572.60
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00305
PINC
0000305
Criticality code
X
II
0
DEMIL code
D
NIIN assigned
14-MAR-76
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8529109000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$1,572.601709B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,572.60170-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
405067856232
LOCKHEED MARTIN CORPORATION DIV RMS - MITCHEL FIELD
A595HDB
283722954647
MICROTECH INC DBA MICROTECH INC
A525ZZ
405067802769
LOCKHEED MARTIN CORPORATION DIV RMS
A525HD
28372290R8N4
ADVANCED TECHNICAL MATERIALS, INC. DBA A T M
H595ZZB
283722910001
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
A321HD1A

Characteristics

CROSS-SECTIONAL SHAPE STYLE
THREAD CLASS2B
THREAD DIRECTIONALL FLANGES ALL CONNECTION FACILITIES RIGHT-HAND
BEND ANGLE IN DEG90.0
TUBING WALL CONSTRUCTION STYLE
TUBING TWIST ANGLE IN DEG90.0
FLANGE QUANTITY2
FLANGE INSIDE WIDTHALL FLANGES INCHES MINIMUM 1.118 AND INCHES MAXIMUM 1.126
FLANGE INSIDE HEIGHTALL FLANGES INCHES MINIMUM 0.493 AND INCHES MAXIMUM 0.501
FLANGE OUTSIDE WIDTHALL FLANGES INCHES MINIMUM 2.230 AND INCHES MAXIMUM 2.270
FLANGE OUTSIDE HEIGHTALL FLANGES INCHES MINIMUM 1.730 AND INCHES MAXIMUM 1.770
FLANGE OUTSIDE DIAMETERALL FLANGES INCHES MINIMUM 2.995 AND INCHES MAXIMUM 2.998
FLANGE DEPTHALL FLANGES INCHES MINIMUM 0.480 AND INCHES MAXIMUM 0.520
VOLTAGE STANDING WAVE RATIO2.01
INSERTION LOSS IN DECIBELS0.03
WAVEGUIDE OUTSIDE WIDTHINCHES MINIMUM 1.246 AND INCHES MAXIMUM 1.254
NOMINAL THREAD SIZEALL FLANGES ALL CONNECTION FACILITIES INCHES 0.164
WAVEGUIDE INSIDE WIDTHINCHES MINIMUM 1.118 AND INCHES MAXIMUM 1.226
WAVEGUIDE INSIDE HEIGHTINCHES MINIMUM 0.493 AND INCHES MAXIMUM 0.501
WAVEGUIDE OUTSIDE HEIGHTINCHES MINIMUM 0.621 AND INCHES MAXIMUM 0.629
WAVEGUIDE LONGER OFFSET DISTANCEINCHES NOMINAL 1.625
FLANGE CONNECTING FACILITY AND QUANTITYALL FLANGES SINGLE CONNECTION FACILITY THREADED HOLE(S) 8
FLANGE STYLE
WAVEGUIDE OFFSET DISTANCEINCHES MINIMUM 3.117 AND INCHES MAXIMUM 3.133
FLEXIBILITYSINGLE TUBING SEGMENT RIGID
MATERIALSINGLE TUBING SEGMENT COPPER ALLOY
SURFACE TREATMENTSINGLE TUBING SEGMENT OUTSIDE SURFACES PASSIVATE
SURFACE TREATMENTALL FLANGE OUTSIDE SURFACES PASSIVATE
STYLE DESIGNATOR
THREAD SERIES DESIGNATORALL FLANGES ALL CONNECTION FACILITIES UNIFIED NATIONAL COARSE (UNC)

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-SEP-03WP81WP
YB01YB01-APR-91YB81YB
ZW01ZW01-DEC-05ZW81ZW
N9BNDN1C01-JUL-05ZHDGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
HD
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
723
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69FZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.7000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0560
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
02-JAN-1993
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.