Catalog item
Request a quoteWAVEGUIDE ASSEMBLY
5985FSC
01NCB code
033-6989Item number
NIIN 01-033-6989
- Unit price
- $395.30
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- D
Identification
- Item name code
- 00305
- PINC
- 0000305
- Criticality code
- X
- II
- 0
- DEMIL code
- D
- NIIN assigned
- 08-JAN-77
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- P
- Schedule B export code
- 8529109000
- FedMall
- Y
Management
- Effective date
- 01-OCT-2026
- Major organizational entity
- DS
- Acquisition advice code
- J
- Source of supply
- SMS
- Unit of issue
- EA
- Unit of measure quantity
- 0.0000
- Unit price
- $395.30
- Quantity per unit pack
- 1
- Controlled inventory item code
- 7
- Shelf-life code
- 0
- Management control
- -------
- Net price
- $0.00
- USC
- I
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|---|
| 052565 | 34228 L3 TECHNOLOGIES, INC. DIV L3 KEO | A | 3 | 2 | A | TX | |||
| 885F052061 ITEM 52 | 34228 L3 TECHNOLOGIES, INC. DIV L3 KEO | A | 5 | 2 | 5 | HD | 4 | A | |
| 885C052565 | 34228 L3 TECHNOLOGIES, INC. DIV L3 KEO | A | 5 | 9 | A | TX | 4 | B | |
| 885C052565 | 03956 NORTHROP GRUMMAN SYSTEMS CORPORATION | A | C | 1 | 6 | ZZ | AC |
Characteristics
| CROSS-SECTIONAL SHAPE STYLE | |
|---|---|
| TUBING WALL CONSTRUCTION STYLE | |
| FLANGE QUANTITY | 2 |
| FLANGE INSIDE WIDTH | ALL FLANGES INCHES MINIMUM 0.362 |
| FLANGE INSIDE HEIGHT | ALL FLANGES INCHES MINIMUM 0.222 |
| FLANGE OUTSIDE WIDTH | ALL FLANGES INCHES MINIMUM 0.745 AND INCHES MAXIMUM 0.755 |
| FLANGE OUTSIDE HEIGHT | ALL FLANGES INCHES MINIMUM 0.745 AND INCHES MAXIMUM 0.755 |
| FLANGE DEPTH | ALL FLANGES INCHES MINIMUM 0.182 AND INCHES MAXIMUM 0.192 |
| FLANGE CONNECTING HOLE DIAMETER | ALL FLANGES ALL CONNECTION FACILITIES INCHES MINIMUM 0.116 |
| WAVEGUIDE OUTSIDE WIDTH | INCHES MINIMUM 0.358 AND INCHES MAXIMUM 0.362 |
| WAVEGUIDE INSIDE WIDTH | INCHES MINIMUM 0.2785 AND INCHES MAXIMUM 0.2815 |
| WAVEGUIDE INSIDE HEIGHT | INCHES MINIMUM 0.1385 AND INCHES MAXIMUM 0.1415 |
| WAVEGUIDE OUTSIDE HEIGHT | INCHES MINIMUM 0.218 AND INCHES MAXIMUM 0.222 |
| WAVEGUIDE LONGER OFFSET DISTANCE | INCHES MINIMUM 4.490 AND INCHES MAXIMUM 4.510 |
| FLANGE CONNECTING FACILITY AND QUANTITY | ALL FLANGES ALL CONNECTION FACILITIES UNTHREADED HOLE(S) 4 |
| FLANGE STYLE | |
| WAVEGUIDE OFFSET DISTANCE | INCHES MINIMUM 0.458 AND INCHES MAXIMUM 0.478 |
| FLEXIBILITY | SINGLE TUBING SEGMENT FLEXIBLE |
| MATERIAL | ALL TUBING SEGMENT AND FLANGE COPPER ALLOY |
| SURFACE TREATMENT | SINGLE TUBING SEGMENT OUTSIDE SURFACES PLASTIC VINYL |
| SURFACE TREATMENT | SINGLE TUBING SEGMENT INSIDE SURFACES LACQUER |
| STYLE DESIGNATOR | |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
MOE rules
- MOE rule
- DGX1
- MOE CD
- DS
- AMC
- 3
- AMSC
- H
- Date assigned
- 01-NOV-25
- PICA
- GX
- PICA LOA
- 01
- Auth collab
- GX
Freight
- ACTY CD
- HD
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 723
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69FZ
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- XXX
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- UItems or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
- Unit pack weight
- 0.1000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0070
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
- Supplemental instructions
- IP025: PACKAGING, MARKING,
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 07-SEP-1988
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.