Catalog item
Request a quoteWAVEGUIDE ASSEMBLY
5985FSC
01NCB code
137-3767Item number
NIIN 01-137-3767
- Unit price
- $19,474.87
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- D
Identification
- Item name code
- 00305
- PINC
- 0000305
- Criticality code
- X
- II
- 0
- DEMIL code
- D
- DEMIL integrity code
- 1
- NIIN assigned
- 25-AUG-82
- Precious metals indicator
- S
- Hazardous material indicator
- P
- Schedule B export code
- 8529109000
- FedMall
- Y
Management
- Effective date
- 01-OCT-2026
- Major organizational entity
- DS
- Acquisition advice code
- J
- Source of supply
- SMS
- Unit of issue
- EA
- Unit of measure quantity
- 0.0000
- Unit price
- $19,474.87
- Quantity per unit pack
- 1
- Controlled inventory item code
- 7
- Shelf-life code
- 0
- Recoverability code
- N
- Management control
- -------
- Net price
- $0.00
- USC
- I
Part numbers
Characteristics
| CROSS-SECTIONAL SHAPE STYLE | |
|---|---|
| TUBING WALL CONSTRUCTION STYLE | |
| FLANGE QUANTITY | 3 |
| FLANGE INSIDE WIDTH | SECOND FLANGE INCHES MINIMUM 1.253 AND INCHES MAXIMUM 1.256 |
| FLANGE INSIDE HEIGHT | SECOND FLANGE INCHES MINIMUM 0.628 AND INCHES MAXIMUM 0.631 |
| FLANGE OUTSIDE WIDTH | SECOND FLANGE INCHES MINIMUM 1.860 AND INCHES MAXIMUM 1.890 |
| FLANGE OUTSIDE HEIGHT | SECOND FLANGE INCHES MINIMUM 1.860 AND INCHES MAXIMUM 1.890 |
| FLANGE DEPTH | SECOND FLANGE INCHES MINIMUM 0.423 AND INCHES MAXIMUM 0.453 |
| FLANGE CONNECTING HOLE DIAMETER | SECOND FLANGE ALL CONNECTION FACILITIES INCHES MINIMUM 0.169 AND INCHES MAXIMUM 0.172 |
| VOLTAGE STANDING WAVE RATIO | 1.10 |
| INSERTION LOSS IN DECIBELS | 0.04 |
| MAXIMUM OPERATING PRESSURE | POUNDS PER SQUARE INCH GAGE 15.0 |
| OPERATING PRESSURE | POUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM 15 |
| FLANGE CONNECTING FACILITY AND QUANTITY | ALL FLANGES THIRD CONNECTION FACILITY UNTHREADED HOLE(S) 6 |
| FLANGE CONNECTING FACILITY AND QUANTITY | ALL FLANGES SECOND CONNECTION FACILITY UNTHREADED HOLE(S) 4 |
| FLANGE STYLE | |
| WAVEGUIDE LENGTH | INCHES NOMINAL 23.460 |
| FLEXIBILITY | SECOND TUBING SEGMENT RIGID |
| FLEXIBILITY | FIRST TUBING SEGMENT FLEXIBLE |
| MATERIAL | FIRST FLANGE ALUMINUM ALLOY |
| MATERIAL | FIRST TUBING SEGMENT COPPER ALLOY |
| MATERIAL | SECOND TUBING SEGMENT ALUMINUM ALLOY |
| PRECIOUS MATERIAL AND LOCATION | SILVER FLEXIBLE WAVEGUIDE INTERNAL SURFACES |
| PRECIOUS MATERIAL | SILVER |
| PROPRIETARY CHARACTERISTICS | PACS |
| SURFACE TREATMENT | SECOND TUBING SEGMENT AND FLANGE OUTSIDE SURFACES ANODIZE AND PAINT |
| SURFACE TREATMENT | FIRST TUBING SEGMENT INSIDE SURFACES SILVER |
| STYLE DESIGNATOR |
MOE rules
- MOE rule
- DGX1
- MOE CD
- DS
- AMC
- 5
- AMSC
- H
- Date assigned
- 01-APR-26
- PICA
- GX
- PICA LOA
- 01
- Auth collab
- GX
Freight
- ACTY CD
- TX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 723
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 41Watervaporproof bag, heat sealed
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- NAPPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
- THK
- C3/4 inch thick
- Unit cont
- ECASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- DOAny suitable fiber box included in this table may be used (see J.4.9.1).
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- UItems or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
- Unit pack weight
- 3.2000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.1300
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 27-AUG-1982
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.