Catalog item

SWITCH,RADIO FREQUENCY TRANSMISS

5985FSC
01NCB code
146-1992Item number
NIIN 01-146-1992
Request a quote
Unit price
$1,608.14
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
05298
PINC
0005298
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
26-JAN-83
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
ESD/EMI code
A
Schedule B export code
8529109000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$1,608.14170NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$1,608.141709B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,608.14170N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
CS-38S13-1124022
TELEDYNE DEFENSE ELECTRONICS, LLC DBA TELEDYNE MICROWAVE SOLUTIONS
A595TXB
CR-38S1324022
TELEDYNE DEFENSE ELECTRONICS, LLC DBA TELEDYNE MICROWAVE SOLUTIONS
A595ZZB
CR-38S13024022
TELEDYNE DEFENSE ELECTRONICS, LLC DBA TELEDYNE MICROWAVE SOLUTIONS
A525ZZ
290099P194117
BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC. DBA BAE SYSTEMS
A32ATX
8031-D0-A4D-4C2-99899
NARDA HOLDINGS, INC. DBA NARDA-MITEQ
A596ZZB
8031-DO-A-4D-4C2-SN99899
NARDA HOLDINGS, INC. DBA NARDA-MITEQ
A525ZZ

Characteristics

BODY STYLE
OVERALL LENGTHINCHES MAXIMUM 2.320
OVERALL HEIGHTINCHES NOMINAL 1.750
OVERALL WIDTHINCHES NOMINAL 1.750
FREQUENCY RATINGSINGLE FREQUENCY RF POWER HANDLING GIGAHERTZ MINIMUM 0.0 AND GIGAHERTZ MAXIMUM 18.0
FREQUENCY RATINGFIRST FREQUENCY INSERTION LOSS REFERENCE GIGAHERTZ MINIMUM 0.0 AND GIGAHERTZ MAXIMUM 6.0
FREQUENCY RATINGSECOND FREQUENCY INSERTION LOSS REFERENCE GIGAHERTZ MINIMUM 6.0 AND GIGAHERTZ MAXIMUM 12.0
FREQUENCY RATINGTHIRD FREQUENCY INSERTION LOSS REFERENCE GIGAHERTZ MINIMUM 12.0 AND GIGAHERTZ MAXIMUM 18.0
FREQUENCY RATINGSECOND FREQUENCY VOLTAGE STANDING WAVE RATIO GIGAHERTZ MINIMUM 6.0 AND GIGAHERTZ MAXIMUM 12.0
FREQUENCY RATINGFIRST FREQUENCY VOLTAGE STANDING WAVE RATIO GIGAHERTZ MINIMUM 0.0 AND GIGAHERTZ MAXIMUM 6.0
FREQUENCY RATINGTHIRD FREQUENCY VOLTAGE STANDING WAVE RATIO GIGAHERTZ MINIMUM 12.0 AND GIGAHERTZ MAXIMUM 18.0
SWITCH TYPENONTRANSFER
OPERATING TEMP RANGECELSIUS -40.0 TO 85.0
END ITEM IDENTIFICATIONAN/USM-464
COAXIAL CONNECTOR SERIES DESIGNATIONSMA
CONNECTOR END DESIGNFEMALE
ACTUATOR CURRENT TYPE AND RATING IN AMPSDC MAXIMUM 0.21
ACTUATOR VOLTAGE IN VOLTSMINIMUM 26.0 AND MAXIMUM 30.0
SWITCH OPERATION SEQUENCEBREAKS BEFORE MAKES
SWITCHING TIMEMILLISECONDS 20.0
SWITCH RETURN MECHANISM TYPEFAIL-SAFE
POLE QUANTITY1
THROW QUANTITY3
RF MAXIMUM VOLTAGE RATINGVOLTS RMS 500.0
COUPLING POSITION QUANTITY4
TERMINAL TYPE AND QUANTITYWIRE HOOK 4 AND RECEPTACLE, COAXIAL 4

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-APR-07WP81WP
YB01YB01-APR-91YB81YB
ZC01ZC01-APR-91ZC81ZC
FXGXDF1L01-JUL-05ZSXGX01SX5DGX TUFXTX
N9BNDN1L01-JUL-05ZKEGX01GH5DGXKE GTN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
42
Container, watervaporproof bag, heat sealed, container
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
EA
MIL-DTL-17667, neutral wrapping paper
Cush dun
DA
A-A-1051, paperboard cushioning
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
1.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
03058

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
28-JAN-1983
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.