Catalog item

WAVEGUIDE ASSEMBLY

5985FSC
01NCB code
303-4819Item number
NIIN 01-303-4819
Request a quote
Unit price
$637.85
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00305
PINC
0000305
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
30-JUN-89
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8529109000
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFZSMSEA0.0000$637.85170NSF9EH-N$0.00F
01-OCT-2026DSZSMSEA0.0000$637.85170N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
MTPS62-501-N-3A54647
MICROTECH INC DBA MICROTECH INC
A52EZZ
TFT-57-4-A-3-N06351
MICROWAVE ENGINEERING CORPORATION
A32ETX

Characteristics

CROSS-SECTIONAL SHAPE STYLE
THREAD CLASS2B
THREAD DIRECTIONSECOND FLANGE ALL CONNECTION FACILITIES RIGHT-HAND
TUBING WALL CONSTRUCTION STYLE
FLANGE QUANTITY2
FLANGE INSIDE WIDTHSECOND FLANGE INCHES MINIMUM 0.620 AND INCHES MAXIMUM 0.624
FLANGE INSIDE WIDTHFIRST FLANGE INCHES MINIMUM 0.703 AND INCHES MAXIMUM 0.708
FLANGE INSIDE HEIGHTFIRST FLANGE INCHES MINIMUM 0.505 AND INCHES MAXIMUM 0.511
FLANGE INSIDE HEIGHTSECOND FLANGE INCHES MINIMUM 0.309 AND INCHES MAXIMUM 0.311
FLANGE OUTSIDE WIDTHFIRST FLANGE INCHES MINIMUM 1.298 AND INCHES MAXIMUM 1.328
FLANGE OUTSIDE WIDTHSECOND FLANGE INCHES MINIMUM 1.298 AND INCHES MAXIMUM 1.328
FLANGE OUTSIDE HEIGHTSECOND FLANGE INCHES MINIMUM 1.298 AND INCHES MAXIMUM 1.328
FLANGE OUTSIDE HEIGHTFIRST FLANGE INCHES MINIMUM 1.298 AND INCHES MAXIMUM 1.328
FLANGE DEPTHFIRST FLANGE INCHES MINIMUM 0.298 AND INCHES MAXIMUM 0.328
FLANGE DEPTHSECOND FLANGE INCHES MINIMUM 0.360 AND INCHES MAXIMUM 0.390
FLANGE CONNECTING HOLE DIAMETERFIRST FLANGE ALL CONNECTION FACILITIES INCHES MINIMUM 0.341 AND INCHES MAXIMUM 0.347
WAVEGUIDE OUTSIDE WIDTHINCHES NOMINAL 1.250
NOMINAL THREAD SIZESECOND FLANGE ALL CONNECTION FACILITIES INCHES 0.138
WAVEGUIDE INSIDE WIDTHINCHES NOMINAL 1.122
WAVEGUIDE INSIDE HEIGHTINCHES NOMINAL 0.497
WAVEGUIDE OUTSIDE HEIGHTINCHES NOMINAL 0.625
FLANGE CONNECTING FACILITY AND QUANTITYSECOND FLANGE ALL CONNECTION FACILITIES THREADED HOLE(S) 4
FLANGE CONNECTING FACILITY AND QUANTITYFIRST FLANGE ALL CONNECTION FACILITIES UNTHREADED HOLE(S) 4
FLANGE STYLE
WAVEGUIDE LENGTHINCHES NOMINAL 3.000
FLEXIBILITYSINGLE TUBING SEGMENT FLEXIBLE
MATERIALALL FLANGE ALUMINUM ALLOY
MATERIALSINGLE TUBING SEGMENT RUBBER
STYLE DESIGNATOR
THREAD SERIES DESIGNATORSECOND FLANGE ALL CONNECTION FACILITIES UNIFIED NATIONAL COARSE (UNC)

MOE rules

MOE rule
FXGX
MOE CD
DF
AMC
3
AMSC
C
Date assigned
01-APR-06
IMC
Z
IMCA
SX
PICA
GX
PICA LOA
01
SICA
SX
SICA LOA
5D
Auth collab
GX TU
Fmr MOE rl
FXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TH
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
723
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69FZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.4000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0880
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
05-JUL-1989
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.