Catalog item

WAVEGUIDE ASSEMBLY

5985FSC
01NCB code
318-7868Item number
NIIN 01-318-7868
Request a quote
Unit price
$2,139.47
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00305
PINC
0000305
Criticality code
X
II
0
DEMIL code
D
NIIN assigned
25-APR-90
Precious metals indicator
S
Hazardous material indicator
P
Schedule B export code
8529109000

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
Y
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$2,139.47
Quantity per unit pack
1
Controlled inventory item code
7
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
951431-503B150
RAYTHEON COMPANY DBA RAYTHEON CO
A32ATX
951431-5049956
RAYTHEON COMPANY DIV CORP
A59ATXB
951431-5054X10
RAYTHEON COMPANY
A525ZZ

Characteristics

CROSS-SECTIONAL SHAPE STYLE
THREAD CLASS2B
THREAD DIRECTIONFIRST FLANGE ALL CONNECTION FACILITIES RIGHT-HAND
BEND ANGLE IN DEG90.0
END ITEM IDENTIFICATIONRADIO TERMINAL SET AN/TRC-170
TUBING WALL CONSTRUCTION STYLE
TUBING TWIST TYPETHIRD TUBING SEGMENT STRAIGHT TWIST
TUBING TWIST ANGLE IN DEG90.0
FLANGE QUANTITY2
FLANGE INSIDE WIDTHFIRST FLANGE INCHES MINIMUM 1.867 AND INCHES MAXIMUM 1.877
FLANGE INSIDE HEIGHTFIRST FLANGE INCHES MINIMUM 0.867 AND INCHES MAXIMUM 0.877
FLANGE OUTSIDE DIAMETERFIRST FLANGE INCHES MINIMUM 3.610 AND INCHES MAXIMUM 3.640
FLANGE DEPTHFIRST FLANGE INCHES MINIMUM 0.922 AND INCHES MAXIMUM 0.953
VOLTAGE STANDING WAVE RATIO1.15
WAVEGUIDE OUTSIDE WIDTHINCHES MINIMUM 1.995 AND INCHES MAXIMUM 2.005
NOMINAL THREAD SIZEFIRST FLANGE ALL CONNECTION FACILITIES INCHES 0.190
OPERATING PRESSUREPOUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM 15.0
WAVEGUIDE INSIDE WIDTHINCHES MINIMUM 1.867 AND INCHES MAXIMUM 1.877
WAVEGUIDE INSIDE HEIGHTINCHES MINIMUM 0.867 AND INCHES MAXIMUM 0.877
WAVEGUIDE OUTSIDE HEIGHTINCHES MINIMUM 0.995 AND INCHES MAXIMUM 1.005
FLANGE CONNECTING FACILITY AND QUANTITYFIRST FLANGE ALL CONNECTION FACILITIES THREADED HOLE(S) 8
FLANGE STYLE
WAVEGUIDE LENGTHINCHES MINIMUM 17.690 AND INCHES MAXIMUM 17.810
WAVEGUIDE CENTER TO CENTER DISTANCEINCHES MINIMUM 3.940 AND INCHES MAXIMUM 4.060
FLEXIBILITYTHIRD TUBING SEGMENT FLEXIBLE
FLEXIBILITYSECOND TUBING SEGMENT RIGID
FLEXIBILITYFIRST TUBING SEGMENT RIGID
MATERIALALL FLANGE ALUMINUM ALLOY 6061
MATERIALTHIRD TUBING SEGMENT COPPER ALLOY
MATERIALFIRST TUBING SEGMENT ALUMINUM ALLOY 6061
MATERIALSECOND TUBING SEGMENT ALUMINUM ALLOY 6061
PRECIOUS MATERIAL AND LOCATIONSILVER INTERNAL WAVEGUIDE SURFACES
PRECIOUS MATERIALSILVER
SURFACE TREATMENTTHIRD TUBING SEGMENT INSIDE SURFACES SILVER
SURFACE TREATMENTFIRST TUBING SEGMENT ALL SURFACES CHROMATE
SURFACE TREATMENTALL FLANGE ALL SURFACES CHROMATE
SURFACE TREATMENTSECOND TUBING SEGMENT ALL SURFACES CHROMATE
STYLE DESIGNATOR
THREAD SERIES DESIGNATORFIRST FLANGE ALL CONNECTION FACILITIES UNF
FSC APPLICATION DATACOMMUNICATIONS EQUIPMENT

MOE rules

MOE rule
DGX1
MOE CD
DS
AMC
3
AMSC
C
Date assigned
01-NOV-05
PICA
GX
PICA LOA
01
Auth collab
GX
Supp collab
TX
Fmr MOE rl
DTX1

Freight

ACTY CD
TH
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
723
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69FZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
4.5000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
1.2060
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
28-APR-1990
NIIN status code
0

Request a quote