Catalog item

WAVEGUIDE ASSEMBLY

5985FSC
01NCB code
333-4302Item number
NIIN 01-333-4302
Request a quote
Unit price
$1,078.99
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00305
PINC
0000305
Criticality code
X
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
03-FEB-91
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8529109000
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$1,078.991Y0NSF9FD-P$0.00F
01-OCT-2026DSJSMSEA0.0000$1,078.991Y0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
23164854647
MICROTECH INC DBA MICROTECH INC
A325ZZ
8811-1120-112115
DRS ICAS, LLC
R79ATX

Characteristics

CROSS-SECTIONAL SHAPE STYLE
THREAD CLASS2B
THREAD DIRECTIONFIRST FLANGE ALL CONNECTION FACILITIES RIGHT-HAND
END ITEM IDENTIFICATIONTRANSMITTING SET,RADAR AN/TPT-T1(V)
TUBING WALL CONSTRUCTION STYLE
FLANGE QUANTITY2
FLANGE INSIDE WIDTHSECOND FLANGE INCHES MINIMUM 1.253 AND INCHES MAXIMUM 1.256
FLANGE INSIDE HEIGHTSECOND FLANGE INCHES MINIMUM 0.628 AND INCHES MAXIMUM 0.631
FLANGE OUTSIDE WIDTHFIRST FLANGE INCHES MINIMUM 1.860 AND INCHES MAXIMUM 1.890
FLANGE OUTSIDE WIDTHSECOND FLANGE INCHES MINIMUM 1.860 AND INCHES MAXIMUM 1.890
FLANGE OUTSIDE HEIGHTSECOND FLANGE INCHES MINIMUM 1.860 AND INCHES MAXIMUM 1.890
FLANGE OUTSIDE HEIGHTFIRST FLANGE INCHES MINIMUM 1.860 AND INCHES MAXIMUM 1.890
FLANGE INSIDE DIAMETERFIRST FLANGE INCHES MINIMUM 1.610 AND INCHES MAXIMUM 1.640
FLANGE DEPTHFIRST FLANGE INCHES MINIMUM 0.610 AND INCHES MAXIMUM 0.640
FLANGE DEPTHSECOND FLANGE INCHES MINIMUM 0.423 AND INCHES MAXIMUM 0.453
FLANGE CONNECTING HOLE DIAMETERALL FLANGES ALL CONNECTION FACILITIES INCHES MINIMUM 0.169 AND INCHES MAXIMUM 0.172
VOLTAGE STANDING WAVE RATIO1.12
INSERTION LOSS IN DECIBELS0.10
THREAD QUANTITY PER INCH32
WAVEGUIDE OUTSIDE WIDTHINCHES MINIMUM 1.246 AND INCHES MAXIMUM 1.254
NOMINAL THREAD SIZEFIRST FLANGE ALL CONNECTION FACILITIES INCHES 0.164
OPERATING PRESSUREPOUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM 25.0
WAVEGUIDE INSIDE WIDTHINCHES MINIMUM 1.118 AND INCHES MAXIMUM 1.126
WAVEGUIDE INSIDE HEIGHTINCHES MINIMUM 0.493 AND INCHES MAXIMUM 0.501
WAVEGUIDE OUTSIDE HEIGHTINCHES MINIMUM 0.621 AND INCHES MAXIMUM 0.629
FLANGE CONNECTING FACILITY AND QUANTITYSECOND FLANGE ALL CONNECTION FACILITIES UNTHREADED HOLE(S) 4
FLANGE CONNECTING FACILITY AND QUANTITYFIRST FLANGE ALL CONNECTION FACILITIES THREADED HOLE(S) 4
FLANGE STYLE
WAVEGUIDE LENGTHINCHES MINIMUM 7.220 AND INCHES MAXIMUM 7.280
WAVEGUIDE CENTER TO CENTER DISTANCEINCHES MINIMUM 1.410 AND INCHES MAXIMUM 1.470
SPECIAL FEATURESFREQUENCY RANGE 7.7 GHZ TO 8.5 GHZ
FLEXIBILITYFIRST TUBING SEGMENT RIGID
FLEXIBILITYSECOND TUBING SEGMENT FLEXIBLE
MATERIALSINGLE TUBING JACKET PLASTIC SILICONE
MATERIALFIRST TUBING SEGMENT ALUMINUM ALLOY
MATERIALSECOND TUBING SEGMENT COPPER ALLOY
SURFACE TREATMENTALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES PAINT
STYLE DESIGNATOR
THREAD SERIES DESIGNATORFIRST FLANGE ALL CONNECTION FACILITIES UNIFIED NATIONAL COARSE (UNC)
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT

MOE rules

MOE rule
FUGX
MOE CD
DF
AMC
3
AMSC
C
Date assigned
01-JAN-11
IMC
Z
IMCA
SU
PICA
GX
PICA LOA
01
SICA
SU
SICA LOA
5D
Auth collab
GX TU
Fmr MOE rl
FUU5

Service data

Air Force

Fund
SF
Budget
9
MMAC
FD
PVC
P
ERRC
N

Freight

ACTY CD
TH
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
723
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
START_OF_HAZARDOUS_PACKAGI

Packaging instructions

PICA SICA
P
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
02-JUL-1994
NIIN status code
0

Request a quote