Catalog item

WAVEGUIDE ASSEMBLY

5985FSC
01NCB code
342-4019Item number
NIIN 01-342-4019
Request a quote
Unit price
$615.04
Unit of issue
EA
Source of supply
SMS
DEMIL code
D

Identification

Item name code
00305
PINC
0000305
Criticality code
X
II
0
DEMIL code
D
NIIN assigned
22-JUL-91
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8529109000
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$615.041709B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$615.04170-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
3452593-193346
CAES SYSTEMS LLC
A32ATX
R130-48706351
MICROWAVE ENGINEERING CORPORATION
A526TX

Characteristics

CROSS-SECTIONAL SHAPE STYLE
THREAD CLASS2B
THREAD DIRECTIONALL FLANGES FIRST CONNECTION FACILITY RIGHT-HAND
BEND ANGLE IN DEG90.0
TUBING WALL CONSTRUCTION STYLE
FLANGE QUANTITY2
FLANGE INSIDE WIDTHALL FLANGES INCHES MINIMUM 0.688 AND INCHES MAXIMUM 0.694
FLANGE INSIDE HEIGHTALL FLANGES INCHES MINIMUM 0.318 AND INCHES MAXIMUM 0.324
FLANGE OUTSIDE WIDTHALL FLANGES INCHES MINIMUM 1.360 AND INCHES MAXIMUM 1.390
FLANGE OUTSIDE HEIGHTALL FLANGES INCHES MINIMUM 1.360 AND INCHES MAXIMUM 1.390
FLANGE DEPTHALL FLANGES INCHES MINIMUM 0.235 AND INCHES MAXIMUM 0.265
FLANGE CONNECTING HOLE DIAMETERALL FLANGES SECOND CONNECTION FACILITY INCHES MINIMUM 0.0960 AND INCHES MAXIMUM 0.0965
FLANGE CONNECTING HOLE DIAMETERALL FLANGES THIRD CONNECTION FACILITY INCHES MINIMUM 0.0937 AND INCHES MAXIMUM 0.0939
VOLTAGE STANDING WAVE RATIO1.15
INSERTION LOSS IN DECIBELS0.20
WAVEGUIDE OUTSIDE WIDTHINCHES MINIMUM 0.788 AND INCHES MAXIMUM 0.794
NOMINAL THREAD SIZEALL FLANGES FIRST CONNECTION FACILITY INCHES 0.138
WAVEGUIDE INSIDE WIDTHINCHES MINIMUM 0.688 AND INCHES MAXIMUM 0.694
WAVEGUIDE INSIDE HEIGHTINCHES MINIMUM 0.318 AND INCHES MAXIMUM 0.324
WAVEGUIDE OUTSIDE HEIGHTINCHES MINIMUM 0.418 AND INCHES MAXIMUM 0.424
WAVEGUIDE LONGER OFFSET DISTANCEINCHES NOMINAL 1.610
FLANGE CONNECTING FACILITY AND QUANTITYALL FLANGES FIRST CONNECTION FACILITY THREADED HOLE(S) 4
FLANGE CONNECTING FACILITY AND QUANTITYALL FLANGES THIRD CONNECTION FACILITY UNTHREADED HOLE(S) 2
FLANGE CONNECTING FACILITY AND QUANTITYALL FLANGES SECOND CONNECTION FACILITY UNTHREADED HOLE(S) 2
FLANGE STYLE
WAVEGUIDE OFFSET DISTANCEINCHES NOMINAL 0.925
SPECIAL FEATURESPOWER RATING 800 WATTS AVERAGE
FLEXIBILITYSINGLE TUBING SEGMENT RIGID
MATERIALSINGLE TUBING SEGMENT AND FLANGE ALUMINUM ALLOY
STYLE DESIGNATOR
THREAD SERIES DESIGNATORALL FLANGES FIRST CONNECTION FACILITY UNIFIED NATIONAL COARSE (UNC)
FSC APPLICATION DATAANTENNAS,WAVEGUIDE AND RELATED EQUIPMENT

MOE rules

MOE rule
N9BN
MOE CD
DN
AMC
1
AMSC
C
Date assigned
01-JUL-05
IMC
Z
IMCA
KE
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX
Supp collab
KE
Fmr MOE rl
N9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
723
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.4000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0050
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
27-JUL-1991
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.