Catalog item

SWITCH,RADIO FREQUENCY TRANSMISS

5985FSC
01NCB code
390-0645Item number
NIIN 01-390-0645
Request a quote
Unit price
$2,717.58
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
05298
PINC
0005298
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
11-MAY-94
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
ESD/EMI code
A
Schedule B export code
8529109000
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$2,717.581U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$2,717.581U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
CDS0622/B128983
DAICO INDUSTRIES, INC. DBA DAICO INDUSTRIES INC
A525ZZ
6011851-00312436
BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC. DIV BAE SYSTEMS INFORMATION & ELECTRONIC SYSTEMS INTEGRATION INC
A39AZZ

Characteristics

BODY STYLE
OVERALL LENGTHINCHES MINIMUM 1.500
OVERALL HEIGHTINCHES MINIMUM 1.000
OVERALL WIDTHINCHES MINIMUM 0.400
FREQUENCY RATINGSECOND FREQUENCY INSERTION LOSS REFERENCE MEGAHERTZ MINIMUM 100.0 AND MEGAHERTZ MAXIMUM 1000.0
FREQUENCY RATINGFIRST FREQUENCY INSERTION LOSS REFERENCE MEGAHERTZ MINIMUM 20.0 AND MEGAHERTZ MAXIMUM 100.0
FREQUENCY RATINGSINGLE FREQUENCY OPERATING MEGAHERTZ MINIMUM 20.0 AND MEGAHERTZ MAXIMUM 2000.0
FREQUENCY RATINGTHIRD FREQUENCY CROSSTALK REFERENCE MEGAHERTZ MINIMUM 1000.0 AND MEGAHERTZ MAXIMUM 2000.0
FREQUENCY RATINGFIRST FREQUENCY CROSSTALK REFERENCE MEGAHERTZ MINIMUM 20.0 AND MEGAHERTZ MAXIMUM 100.0
FREQUENCY RATINGSINGLE FREQUENCY VOLTAGE STANDING WAVE RATIO MEGAHERTZ MINIMUM 20.0 AND MEGAHERTZ MAXIMUM 2000.0
FREQUENCY RATINGSECOND FREQUENCY CROSSTALK REFERENCE MEGAHERTZ MINIMUM 100.0 AND MEGAHERTZ MAXIMUM 1000.0
FREQUENCY RATINGTHIRD FREQUENCY INSERTION LOSS REFERENCE MEGAHERTZ MINIMUM 1000.0 AND MEGAHERTZ MAXIMUM 2000.0
UNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.106
SWITCH TYPENONTRANSFER
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERSSINGLE MOUNTING FACILITY PATTERN INCHES NOMINAL 1.300
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERSSINGLE MOUNTING FACILITY PATTERN INCHES NOMINAL 0.800
SHORTEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERSSINGLE MOUNTING FACILITY PATTERN INCHES NOMINAL 0.800
OPERATING TEMP RANGECELSIUS -55.0 TO 125.0
VOLTAGE STANDING WAVE RATIO1.30
INSERTION LOSS IN DECIBELS2.00
INSERTION LOSS IN DECIBELS1.00
INSERTION LOSS IN DECIBELS1.25
MINIMUM CROSSTALK RATING IN DECIBELS50.0
MINIMUM CROSSTALK RATING IN DECIBELS75.0
MINIMUM CROSSTALK RATING IN DECIBELS60.0
ACTUATOR OPERATING METHODRELAY
ACTUATOR CURRENT TYPE AND RATING IN AMPSDC MAXIMUM 0.012
ACTUATOR VOLTAGE IN VOLTSMINIMUM 4.75 AND MAXIMUM 5.25
SWITCH OPERATION SEQUENCEMAKES BEFORE BREAKS
SWITCHING TIMEMICROSECONDS 3.0
SWITCH RETURN MECHANISM TYPEFAIL-SAFE
POLE QUANTITY1
THROW QUANTITY2
COUPLING POSITION QUANTITY3
MOUNTING FACILITY TYPE AND QUANTITYUNTHREADED HOLE(S) 4
MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY PATTERN FOUR POSITION RECTANGULAR
TERMINAL TYPE AND QUANTITYPIN 4

MOE rules

MOE rule
FXGX
MOE CD
DF
AMC
3
AMSC
C
Date assigned
01-APR-06
IMC
Z
IMCA
SX
PICA
GX
PICA LOA
01
SICA
SX
SICA LOA
5D
Auth collab
GX TU
Fmr MOE rl
FXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TH
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
39
ESD sensitive electronic device requirements of MIL-STD-129 apply
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
ESD AND PHYSICAL PROTECTIO

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
14-MAY-1994
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.