Catalog item
Request a quoteMOTOR,DIRECT CURRENT
6105FSC
00NCB code
752-2124Item number
NIIN 00-752-2124
- Unit price
- $470.02
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 16350
- PINC
- 0016350
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-JAN-62
- Precious metals indicator
- A
- Hazardous material indicator
- N
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DA | J | SMS | EA | 0.0000 | $470.02 | 1 | U | 0 | Z | J2200X- | $0.00 | A |
| 01-OCT-2026 | DF | J | SMS | EA | 0.0000 | $470.02 | 1 | U | 0 | N | SF9---V | $0.00 | F |
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $470.02 | 1 | U | 0 | 9B----- | $0.00 | N | |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $470.02 | 1 | U | 0 | N | ------- | $0.00 | I |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| 110A122 | 25140 GLOBE MOTORS, INC. DBA ALLIENT DAYTON | A | 3 | 2 | X | XX | 3 | D |
| SMB343918 | 80063 US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR | A | E | 8 | B | CX | ||
| SMD343919 | 80063 US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR | A | 5 | 1 | B | CX | 3 | D |
| B343918 | 98738 HERLEY CHICAGO DBA STEWART WARNER ELECTRONICS | A | 3 | 2 | X | XX | 3 | D |
| 5303 | 08719 DUCOMMUN LABARGE TECHNOLOGIES, INC DBA DUCOMMUN LABARGE TECHNOLOGIES, INC | A | 3 | 2 | 5 | ZZ | D | |
| 230-0343-000 | 13499 ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS | A | 3 | 2 | 5 | CX | 3 | D |
| 230-0343-00 | 13499 ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS | A | 5 | 9 | X | XX | 3 | D |
| 4609 | 13685 NORTHFIELD ELECTRIC MOTOR CO INC | H | 5 | 9 | 5 | CX |
Characteristics
| ENCLOSURE FEATURE | TOTALLY ENCLOSED |
|---|---|
| WINDING TYPE | SERIES WOUND |
| MOUNTING METHOD | FIXED BASE |
| OVERALL LENGTH | INCHES 3.032 |
| LENGTH OF SHAFT FROM HOUSING | SINGLE END INCHES 0.407 |
| SHAFT CENTER TO MOUNTING SURFACE DISTANCE | SINGLE END INCHES 1.000 |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | INCHES 1.375 |
| TEMP RATING | OPERATING CELSIUS -55.0 AND OPERATING CELSIUS 75.0 |
| OVERALL HEIGHT | INCHES 1.906 |
| SHAFT END CHARACTERISTIC | SINGLE END SINGLE STYLE A1 |
| PROPRIETARY CHARACTERISTICS | PACS |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 2 |
| MAXIMUM OPERATING ALTITUDE RATING | FEET 18000.0 |
| SHAFT ROTATION DIRECTION | SINGLE END CLOCKWISE |
| DUTY CYCLE | INTERMITTENT |
| COOLING METHOD | NONVENTILATED |
| MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 3 |
| ROTOR SPEED RATING IN RPM | SINGLE FULL LOAD 7400.0 |
| NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | INCHES 1.531 |
| CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | INPUT LINE TO NEUTRAL SINGLE 26.4 |
| INCLOSURE SPECIFICATION | COMMERCIAL |
| FEATURES PROVIDED | FRAME ELECTRICALLY GROUNDED AND HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
| POWER RATING | OUTPUT HORSEPOWER 0.044 |
| OVERALL WIDTH | INCHES 1.750 |
| SHAFT DIAMETER | SINGLE END INCHES NOMINAL 0.187 |
| TIME INTERVAL | SECONDS MAXIMUM ON 6.0 AND SECONDS MINIMUM OFF 24.0 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WB01 | WB | 01-FEB-05 | WB | 81 | WB | ||||||||
| YB01 | YB | 01-APR-91 | YB | 81 | YB | ||||||||
| YJ01 | YJ | 01-APR-91 | YJ | 81 | YJ | ||||||||
| ZC01 | ZC | 01-APR-91 | ZC | 81 | ZC | ||||||||
| ZH01 | ZH | 01-APR-91 | ZH | 81 | ZH | ||||||||
| ZU01 | ZU | 01-AUG-95 | ZU | 81 | ZU | ||||||||
| ZW01 | ZW | 01-NOV-98 | ZW | 81 | ZW | ||||||||
| A920 | DA | 1 | Q | 01-SEP-06 | Z | CD | GX | 01 | CD | 5D | GX CD | CL CT | A183 |
| FXGG | DF | 1 | Q | 01-SEP-06 | Z | SX | GX | 01 | SX | 5D | GX TU | FXCX | |
| N9BG | DN | 1 | Q | 01-SEP-06 | Z | GH | GX | 01 | GH | 5D | GX | HD | N9GD |
Service data
Army
- Matcat 1
- J
- Matcat 2
- 2
- Matcat 3
- 2
- Matcat 4 5
- 00
- ARC
- X
Navy
- COG
- 9B
Air Force
- Fund
- SF
- Budget
- 9
- PVC
- V
- ERRC
- N
Freight
- ACTY CD
- XX
- NMFC
- 062120
- NMFC sub
- Z
- Uniform freight class
- 34760
- Less than truckload
- W
- Water commodity code
- 593
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- GENERATORS/MOTORS/PARTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 60C0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- 000No intermediate container quantity specified (000)
- Method of preservation
- 10Physical protection
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- 00No requirement.
- Lvl A
- EPacking shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 3.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.3000
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 13873
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- GX
- Dt stdzn dec
- 01-NOV-2007
- NIIN status code
- 0
Cancelled and replaced NIINs
| FSC | Cancelled NIIN | NIIN status code | Effective date | DEMIL code |
|---|---|---|---|---|
| 6105 | 6105-00-003-5261 | 5 | 02-JUL-2026 | A |
| 6105 | 6105-00-760-8203 | 7 | 02-JUL-2026 | A |
| 6105 | 6105-00-990-7066 | 7 | 02-JUL-2026 | A |
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.