Catalog item

CONTACTOR,MAGNETIC

6110FSC
00NCB code
367-1208Item number
NIIN 00-367-1208
Request a quote
Unit price
$337.41
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
31517
PINC
0031517
Criticality code
X
II
M
DEMIL code
A
NIIN assigned
01-JAN-63
Precious metals indicator
A
Hazardous material indicator
N
Schedule B export code
8543909000
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$337.411U0NSF9---N$0.00F
01-OCT-2026DSJSMSEA0.0000$337.411U0N-------$0.00I
01-OCT-2026GPJSMSEA0.0000$337.411U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
135814565054
WESTINGHOUSE ELECTRIC CORP POWER GENERATION-GENERATOR DIV
H596XF1B
135814579500
WESTINGHOUSE ELECTRIC CORP
A326XF1A

Characteristics

ACTUATION METHODMAGNETIC
PERFORMANCE TYPEAUTOMATIC
OPERATING VOLTAGE CHARACTERISTICFULL
AMBIENT TEMPCELSIUS 150.0
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGNDESIGNED PER NEMA STD
CONTROL TYPELOCAL
ENCLOSURE FEATUREOPEN
AC VOLTAGE RATINGVOLTS NOMINAL 600.0
DUTY CYCLECONTINUOUS
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONINDUSTRIAL USE-NEMA TYPE 12

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
C911GP5D01-FEB-05GX01XG5DXG GXC006
FXGGDF5D01-FEB-05ZSXGX01SX5DGX TUFXCX

Service data

Air Force

Fund
SF
Budget
9
PVC
N
ERRC
N

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
590
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
27A0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
E5
ASTM D5118/D5118M, fiberboard box.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14153
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
28-MAR-1971
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.